16
starting cold engine
•Recoil starter: Use short pulls - only
•
1.Throttle Lever
Move throttle position lever (A) midway between idle and full throttle positions.
1.Throttle Position / Stop Switch Button
Slide Throttle Position / Stop Switch Button (A) back to idle posi- tion.
PB-500H, PB-500T
2.Choke
Move choke (C) up to Cold Start position ( ).
3.Purge Bulb
Pump purge bulb (D) until fuel is visible and flows freely in the clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4.Recoil Starter
Pull recoil starter handle (E) until engine fires, or a maximum of 5 pulls.
5.Choke
After engine fires (or 5 pulls), move choke lever (C) to “Run” (
) position, then pull starter handle/rope until engine starts and runs. Allow unit to warm up at idle for several minutes.
NOTE
If engine does not start with choke in “Run” position after 5 pulls,
move choke to “Cold Start” ( ) position, and repeat steps 4 & 5.
6.Throttle Lever
Allow engine to warm up for several minutes before use.
7.Throttle Lever
After engine
C
E
D