8
1. POWER HEAD - Includes the Engine, Clutch, Fuel System, Ignition System and Recoil Starter.
2. GRIP, RIGHT HAND REAR - Cushioned grip for right hand.
3. THROTTLE TRIGGER LOCKOUT - This lever must be held during starting. Operation of the throttle trigger is
prevented unless throttle trigger lockout lever is engaged.
4. STOP SWITCH - mounted on top of the Throttle Trigger Housing. Move switch FORWARD to RUN, BACK to
STOP.
5. DRIVE SHAFT ASSEMBLY - Contains the Flexible Drive Cable.
6. FRONT LEFT HAND LOOP HANDLE - Adjustable, loop handle for proper cutting attitude and operator comfort.
7. BLADES - Double reciprocating blades mounted to a blade support bar. Double sided blades, are capable of
cutting on either side.
8. GEAR HOUSING ASSEMBLY - Gear housing assembly fixed straight extension.
9. THROTTLE TRIGGER - Spring loaded to return to idle when released. During acceleration, depress gradually for
best operating technique.
10. BLADE COVER - Used to cover blade during transport and storage. Remove blade cover before using unit.
11. SPARK PLUG - Provides spark to ignite fuel mixture.
12. TOP GUARD - Protects arm from the hot engine.
13. SPARK ARRESTOR - CATALYTIC MUFFLER / MUFFLER -The muffler or catalytic muffler controls exhaust noise
and emission. The spark arrestor screen prevents hot, glowing particles of carbon from leaving the muffler. Keep
exhaust area clear of flammable debris.
14. FUEL TANK - Contains fuel and fuel filter.
15. FUEL TANK CAP - Covers and seals fuel tank opening.
16. RECOIL STARTER HANDLE - Pull handle slowly until starter engages, then quickly and firmly. When engine
starts, return handle slowly. DO NOT let handle snap back or damage to unit will occur.
17. PRIMER BULB - Pumping primer bulb before starting engine draws fresh fuel from the fuel tank priming the
carburetor for starting. Pump primer bulb until fuel is visible and flows freely in the clear fuel tank return line. Pump
bulb an additional 4 or 5 times.
18. AIR CLEANER - Contains replaceable filter element.
19. CHOKE CONTROL - Located on the air cleaner housing. Move the lever to Cold Start ( ) to close the choke for
Cold Starting. Move lever to Run ( ) position after engine fires.
20. SAFETY VIDEO - (Not included with unit) P/N 99922202800 English version is available at a cost of $5.00 from
ECHO, INC. or any authorized ECHO dealer. The video overviews safety precautions and proper operating tech-
niques and is supplemental to the Safety Manual. Read and understand the Safety Manual for complete information
on safe operation.