Model Ei151TLR Ionisation
Technical Specification
Sensor | Ionisation |
Sensitivity: | Complies with BS 5446 Part 1: |
| 2000 |
Source: | Americium 241 |
Button Test: | Simulates the effect of smoke and |
| checks electronics and horn. |
Supply Voltage: | 230V AC |
Battery | Rechargeable lithium cells |
Continuous green LED | |
Alarm: | Electronic Piezoelectric horn |
| in unit |
Alarm Sound Output: 85dB (minimum) at 3m | |
Alarm Status: | Red LED flashes every second on |
| unit sensing fire |
Temperature Range: | 0° to 40°C |
Humidity Range: | 15% to 95% Relative Humidity |
Remote control: | Ei152, Ei159 or MCP400 |
Interconnect: | Up to 12 interconnected |
| Ei150/151TL/151TLR/154TL/155/1 |
| 56TLH/156TLR smoke or heat |
| alarms, along with an EI158 relay |
| base |
Fixing: | Screw fixings supplied |
Plastic material: | UL94VO flame retardant |
Dimensions: | 140mm x 120mm x 46mm |
Weight: | 227g |
Warranty: | 5 year (limited) warranty |
Approvals: | Kitemarked to BS EN 14604:2005, |
| CE Approved |
Specifications are subject to change
Installation & Placement
Wiring for Interconnected Alarms
Be very careful about correctly wiring the alarms as mixing Live and Neutral will blow/damage interconnected alarms.
Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of areas of “dead air” close to corners of rooms and apexes of ceilings, which could result in the prevention of smoke reaching the smoke detector
Please consult instruction booklet for specific installation details
Important Precaution:
Do not install the actual smoke/heat alarm itself in new or renovated buildings until all work is completed (including floor coverings) and the building has been fully cleaned. The wiring can be installed when appropriate. (Excessive dust and debris from building work can contaminate the smoke chamber and cause problems, and it will also invalidate the guarantee). If it must be installed, cover it completely, particularly around the edges, with a dust cover (eg. a plastic bag), until all cleaning is finished.. Connect wires to the unit as in wiring diagram. All wiring must comply with local codes.