Ei Electronics manual Technical Specification, Installation & Placement, Model Ei168 RF Base

Models: Ei168

1 2
Download 2 pages 15.46 Kb
Page 2
Image 2
Technical Specification

Model Ei168 RF Base

Technical Specification

Sensor

None

Supply Voltage:

230V AC

Battery back-up:

Rechargeable lithium cells

RF Range:

150 meters (min) free space

Range Improvement:

Adjustable antenna

RF Visual Indicator:

Amber light flashes continuously

 

for 1.5 to 3.5 seconds while

 

transmitting RF signal

RF Frequency:

868.499MHZ (1% duty cycle)

RF Power:

+5dBM

Dimensions:

150mm diameter x 19mm depth

Weight:

168g

Installation & Placement

Power-On Indicator: Green light on the attached mains powered alarm can be seen

Alarm characteristics: Available in the attached alarm

Temperature Range:

00 to 400 C

Humidity Range:

15% to 95% Relative Humidity

Interconnect:

Up to 12 RadioLINK products

Plastic material:

UL94VO flame retardant

Warranty:

5 year (limited) warranty

Approvals:

RF performance to EN300220-3

 

EMC performance to EMC 301489-3

Specifications are subject to change

House Code Procedure

Place the Ei168 Base on the ceiling/wall and mark the screw holes. Drill with a suitable drill bit, insert the screw plugs, connect to the nearest mains circuit and screw the base into position.

The RF Bases should be house coded to prevent possible interference from neighbouring installations – see instructions for more details.

Alarms should be placed in accordance with the general guidelines shown in the diagram above. These recommendations are based on the problem of areas of “dead air” close to corners of rooms and apexes of ceilings, which could result in the prevention of smoke reaching the smoke detector

1.Connect the base to the mains circuit and slide on associated alarm.

2.Hold the house code switch (with a small screwdriver) until the yellow light turns on and then release

3.Similarly, place other bases into house code mode

4.Check that the number of yellow flashes (on each base) corresponds to the number of bases in your system

5.Remove all bases from house code

6.Button test each alarm (attached to each base) to check your system