18
original DS-250. Tilt speed will be the same as speed 2.
Mic Sensitivity – This function makes the internal microphone more or less
sensitive to sound. This function only works in conjunction with the sound active
modes. The default setting is 70% and setting range from 0% to 99%.
Hibernation When activated, this function will automatically put the fixture in
power stand-by mode after a defined period of time of no DMX activity. This
prevents the fixture form expending power for extended periods in the event the
fixture has been left on accidently. In stand-by mode the lamp and all motors will
power down if no DMX signal is sent to the fixture for a period of 15 minutes
(default, can be user defined). The fixture will automatically reset and return to
normal operation once a DMX signal is sensed.
Fans Control - This function is used to change the functionality of the internal
cooling fans. The available selections are: 1) “AUTO” – The fans will automatically
switch between low and high speeds depending on the internal operating
temperature. 2) “HIGH” – The fans will run in high-speed mode regardless of
operating temperature. 3) “LOW” – The fans will remain in low speeds regardless of
internal operating temperature.
Display Settings
Shutoff Time - The display is designed to turn off during normal operation to
avoid excessive light in situations that require an extremely dark environment.
This function will adjust the amount of time the display will remain on until it is
automatic turned off. This function is disabled as default.
Display Reverse – This function will allow the entire display to be flipped by
180˚ to allow for better view when the fixture is hung from truss or a ceiling. This
function is disabled as default.
Key Lock – This function allows you to lock the keys on the display to prevent
menu tampering. With this function you can activate the automatic keylock
function. If this function is activated, the keys will be automatically locked in 15
seconds from the last command. In order to deactivate or temporarily deactivate
the keylock function, press the Mode/Esc Button for 3 seconds to regain access to