Platinum Spot 5R™
©Elation Professional, Los Angeles Ca. 15 www.ElationLighting.com
the replacement lamp meets or exceeds the original lamp specifications,
failure to do so may damage the fixture and void the manufactures warranty.
• Be sure to follow all the lamp handling procedures included with the new
lamp. Never handle the new lamp with your bare hands as the oils from your
skin may damage the lamp and cause premature lamp failure.
Installation Procedure:
1. Set the fixture on a flat surface and remove the two screws marked “A” and “B”.
2. Remove the cover plate to access the lamp.
3. Gently remove the old lamp by grasping the ceramic socket base and twisting it
slightly in counter-clockwise direction until it becomes free.
4. Once the lamp becomes free, grasp the ceramic socket and gently pull away from
the lamp.
5. Insert the new lamp securely. The lamp will only seat one way, please be sure to
insert the lamp in the same position as the old one. Before reassembling the unit, be
sure the new lamp is securely seated in the lamp socket. Always be sure to only use
specified lamp types! (Philips MSD Platinum 5R).
6. Once the lamp has been inserted and secured into the socket, follow the lamp
optimization instructions outlined below, then lock the lamp cover back in to place by
securing screws “A” and “B”.
7. Reset the lamp run time in the system menu. If the system run time is not reset the
“Replace the Lamp” warning will continue to flash in the display and fixture will
eventually shut down. To reset the lamp running time follow the procedures below;
A. Activate the menu by pressing the “Mode/Esc” button and toggle to
“Information”