Elation Professional - www.elationlighting.com - ELED Fresnel Instruction Manual Page 10Elation Professional - www.elationlighting.com - ELED Fresnel Instruction Manual Page 9
ELED Fresnel 1 Channel Mode - DMX Values and Functions
Channel Value Function 1 0 - 255 DIMMER 0% - 100% ELED Fresnel 2 Channel Mode - DMX Values and Functions
Channel Value Function 1 0 - 255 DIMMER 0% - 100% 2 0 - 255 STROBING SLOW - FASTELED Fresnel Cleaning
Due to fog residue, smoke, and dust cleaning the internal and exter-
nal optical lenses must be carried out periodically to optimize light
output.
1. Use normal glass cleaner and a soft cloth to wipe down the
outside casing.
2. Clean the external optics with glass cleaner and a soft cloth
every 20 days.
3. Always be sure to dry all parts completely before plugging
the unit back in.
Cleaning frequency depends on the environment in which the fixture
operates (i.e. smoke, fog residue, dust, dew).
ELED Fresnel Trouble Shooting
Listed below are a few common problems the user may encounter,
with solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are
wired correctly (pin 3 is “hot”; on some other DMX devices
pin 2 may be ‘hot’). Also, check that all cables are connected
to the right connectors; it does matter which way the inputs
and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.