Instructions for the Installer
| BURNER | R A P I D | A U X I L I A R Y | T R I P L E | |||||||
TYPE OF GAS |
| ( l a r g e ) | ( m e d i u m ) | ( s m a l l ) | C R O W N | ||||||
|
|
|
|
|
|
|
|
|
| ||
| POSITION | MAX |
| MIN | MAX | MIN | MAX | MIN | MAX | MIN | |
| NOMINAL THERMAL |
|
|
|
|
|
|
|
|
| |
NATURAL GAS | POWER (kW) | 3.0 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | 4.0 | 1.2 | ||
|
|
|
|
|
|
|
|
|
| ||
20 mbar | NOMINAL FLOW |
|
|
|
|
|
|
|
|
| |
VALUE = | RATE (m3/h) | 0.286 | 0.057 | 0.190 | 0.038 | 0.095 | 0.028 | 0.381 | 0.114 | ||
37.78 MJ/m3 | NOZZLE |
|
|
|
|
|
|
|
|
| |
Ws - 50.7 MJ/ m3 | 119 | Adjust. | 96 | Adjust. | 70 | Adjust. | 146 | Adjust. | |||
| REFERENCE | ||||||||||
| (1/100 mm) |
|
|
|
|
|
|
|
|
| |
LPG GAS | NOMINAL THERMAL |
|
|
|
|
|
|
|
|
| |
POWER (kW) | 2.8 | 0.65 | 2.0 | 0.45 | 1.0 | 0.33 | 4.0 | 1.2 | |||
VALUE= | NOMINAL FLOW |
|
|
|
|
|
|
|
|
| |
49.92MJ/Kg |
|
|
|
|
|
|
|
|
| ||
RATE (g/h) | 202 | 43.5 | 144 | 29 | 72 | 21,5 | 252 | 86 | |||
| |||||||||||
| NOZZLE REFERENCE | 86 | 40 | 71 | 32 | 50 | 28 | 98 | 56 | ||
| (1/100 mm) |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
Burner | Dia. Tap |
|
|
|
|
|
|
|
|
1/100 mm
Auxiliary28
Rapid40
Aeration adjustment none
13