Electrical Connection
10
The wire coloured green and yellow must be connected to the termi-
nal marked with the letter “E“ or by the earth symbol or coloured
green and yellow
The wire coloured blue must be connected to the terminal “N“ or col-
oured black.
The wire coloured brown must be connected to the terminal marked
“L“ or coloured red.
Upon completion there must not be cut, or stray strands of wire
present and the cord clamp must be secure over the outer sheath.
1 WARNING: A cut off plug inserted into a 13 amp socket is a seri-
ous safety (shock) hazard. Ensure that the cut off plug is disposed
of safely.

Permanent connection

In the case of a permanent connection it is necessary that you install a
double pole switch between the appliance and the electricity supply
(mains), with a minimum gap of 3 mm between the switch contacts
and of a type suitable for the required load in compliance with the cur-
rent electrical regulations.
The switch must not break the yellow and green earth cable at any
point.