Electrolux 5995615357 installation manual Horizontal Vent Termination- PVC/CPVC Materials Only

Models: 5995615357

1 40
Download 40 pages 44.58 Kb
Page 20
Image 20
t47$POWFSTJPOLJU47$,JTSFRVJSFEGPSUIFBJSJOUBLF.

Vent Pipe Installation (When supplying combustion air from the indoors (SV, non-direct vent))

* Dip switch No.3 is turned on.

t%JTDPOOFDUQPXFSBOEUVSO0/EJQTXJUDIJGDPNCVTUJPOBJSXJMMCF supplied from the indoors as illustrated to the right. Refer to page 29 for the location of the dip switch bank.

t47$POWFSTJPOLJU47$,JTSFRVJSFEGPSUIFBJSJOUBLF.

Vertical Vent Termination- PVC/CPVC Materials OnlyManual background WARNING

'BJMVSFUPQFSGPSNUIFBCPWFTUFQTDPVMESFTVMUJOBàSFPSFYQMPTJPODBVTJOH property damage, personal injury or death.

3FGFSUPUIFJOTUSVDUJPOTQSPWJEFEXJUIUIFDPOWFSTJPOLJUGPSBEEJUJPOBMEFUBJMT

Horizontal Vent Termination- PVC/CPVC Materials Only

 

3” Min.

 

Hanger

Exhaust

Straps

Intake

Slope vent

 

Insert Bird

Upwards

 

 

 

Screen* in

SV Conversion Kit

 

 

 

 

Each End

Accessory

 

 

of Tee

(#SV-CK-3)

**1' (0.3m) Minimum

Inlet screen

 

 

 

 

90 Elbow

 

 

 

 

* Not supplied with water

 

 

heater, order separately.

 

 

**1' (0.3m) Minimum

 

 

 

recommended, but not required.

 

Pipe Material

PVC or CPVC

 

 

Max. Straight Vent Length***

 

No. of Elbows

4" (100mm) Pipe

3" (75mm) Pipe

 

4

35' (10.8m)

35' (10.8m)

 

3

41' (12.6m)

41' (12.6m)

 

2

47' (14.4m)

47' (14.4m)

 

1

53' (16.2m)

53' (16.2m)

 

*** Not including the termination.

CA tee, 45Manual background elbow, or the PVT-HL termination may be used for the vent termination. It is not necessary to use bird screens with the PVT-HL termination.

CTerminate at least 12" (300mm) above grade or above snow line.

CTerminate at least 7' (2.1m) above a public walkway,

6' (1.8m) from the combustion air intake of any appliance, and 3' (0.9m) from any other building opening, gas utility meter, service regulator etc.

CTerminate at least 3' (0.9m) above any forced air inlet within 10' (3m) , 4' (1.2m) below, 4' (1.2m) horizontally from or

1' (0.3m) above any door, window, or gravity air inlet into any building per National Fuel Gas Code ANSI Z223.1/NFPA 54.

CSlope the horizontal vent 1/4" upwards for every 12" (300mm) toward the termination.

CUse a condensation drain if necessary.

C In the Commonwealth of Massachusetts a carbon monoxide detector is required for all side wall horizontally vented gas fuel equipment.

Please refer to Technical Bulletin TB 010606 for full installation instructions.

C When installed in a manufactured home, all combustion air must be supplied from the outdoors as shown on pages 15 - 17.

Vertical Vent Termination- PVC/CPVC Materials Only

Storm Collar Manual background

Insert Bird

Screen* in

End of 90Manual background

Elbow

C Terminate at least 6' (1.8m) from the combustion air intake of any appliance, and 3' (0.9m) from any other building opening, gas utility meter, service regulator etc.

Roof

Flashing

 

 

Firestop/Support

 

Support

 

Exhaust

Hanger

Firestop

Intake

Strap

 

 

 

SV Conversion Kit

 

Accessory

Slope vent

(#SV-CK-3)

Upwards

Inlet screen

**1' (0.3m)

 

 

Minimum

90 Elbow

 

* Not supplied with water heater, order separately.

**1' (0.3m) minimum recommended, but not required.

C Enclose exterior vent systems below the roof line to limit condensation and protect against mechanical failure.

C When the vent penetrates a floor or ceiling and is not running in a fire rated shaft, a firestop and support is required.

C When the vent termination is located not less than 8' (2.4m) from a vertical wall or similar obstruction, terminate above the roof at least 2' (0.6m), but not more than 6' (1.87m), in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54.

C Provide vertical support every 3' (0.9m) or as required by the vent pipe manufacturer's instructions.

C A short horizontal section is recommended to prevent debris from falling into the water heater.

C When using a horizontal section, slope the horizontal vent 1/4” upwards for every 12” (300mm) toward the termination to drain condensate.

C When installed in a manufactured home, all combustion air must be supplied from the outdoors as shown on pages 15 - 17.



Page 20
Image 20
Electrolux 5995615357 installation manual Horizontal Vent Termination- PVC/CPVC Materials Only