25

Ignition System / Gas Ignition

Y E S

Ignitor does not spark

N O

Check plug top fuse and replace if necessary

Check polarity and earth continuity of supply point

Check earth continuity of appliance

Check gas supply at burner

Light burner manually

Check by pass simmer adjusted

Check position of the electrode

Check fitting of burners

Check continuity from 'N' on the mains connector block and "O" on the ignitor unit

Check continuity from 'L' on the mains connector block and the taps ignition switches

Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit

Check for breaks in the insulation of the HT leads

Check continuity from ignition switches connector to ignitor unit

Change the ignitor unit

Page 25
Image 25
Electrolux 65852 G manual Ignition System / Gas Ignition, Ignitor does not spark