21
Unusual noises. The appliance is touching the
wall or other objects.
Appliance is not level.
The compressor starts after a
period of time.
See the "Cleaning and Care"
section.
This is normal, no error has
occurred.
The compressor does not start
immediately after changing
the temperature setting.
Water on the floor or on sto-
rage shelves. Water drain hole is blocked.
Move the appliance slightly.
Readjust the feet.
Changing the light bulb
Warning! There is a risk of electric shocks! Before changing the light bulb,
switch off the appliance and unplug it, or pull the fuse or the circuit breaker.
Light bulb data: replace the lamp with
one of the same power (the maximum
power is shown on the light diffuser).
1. To switch off the appliance, press the
button “A”.
2. Unplug the mains plug.
3. To change the light bulb press on the
rear hook and at the same time slide
the cover in the direction indicated
by the arrow.
4. Change the defective light bulb.
5. Refit the light bulb cover.
6. Put the refrigerator back into opera-
tion.
Malfunction Possible Cause Remedy
If, after carrying out the necessary checks there is still a fault with your
appliance please contact your local AEGService Force Centre.
In guarantee customers should ensure that the suggested checks have
been made as the engineer will make a charge if the fault is not a
mechanical or electrical breakdown.
Please note that proof of purchase is required for any in-guarantee service