Instructions for the Installer
Electrical connections
Any electrical work required to install this hob should be carried out by a qualified electrician or competent person, in accordance with the current regulations.
THIS HOB MUST BE EARTHED.
The manufacturer declines any liability should these safety measures not be observed. This hob is designed to be connected to a
The hob is supplied with a 3 core flexible supply cord incorporating a 3amp plug fitted. In the event of having to change the fuse, a 3amp ASTA approved (BS 1362) fuse must be used.
Should the plug need to be replaced for any reason, the wires in the mains lead are coloured in accordance with the following code:
Green and Yellow | - Earth |
Blue | - Neutral |
Brown | - Live |
1)Connect the green and yellow (earth) wire to the terminal in the plug which is marked
with the letter 'E' or the earth symbol or coloured green and yellow.
2)Connect the blue (neutral) wire to the terminal
in the plug which is marked with the letter 'N' or coloured black.
3)Connect the brown (live) wire to the terminal
in the plug which is marked with the letter 'L' or coloured red.
Upon completion there must be no cut, or stray strands of wire present and the cord clamp must be secure over the outer sheath.
In the event of having to change the fuse, a 3amp ASTA approved (BS 1362) fuse must be used.
A cut off plug inserted into a 13 amp socket is a serious safety (shock) hazard. Ensure that the cut off plug is disposed of safely.
17