Electrolux air-o-chill

Blast Chiller/Freezers 30kg 6GN1/1

Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not allow bacterial growth .Electrolux Blast Chillers/Freezers reduce temperature from +90ºC to +3°C at food core in less than 90 minutes and down to -18ºC in less than four hours: the model detailed on this sheet performs this cycle up to a 30 kg full load. After the Blast Chilling/freezing process a holding cycle starts automatically to respectively maintain food at +3 and -18 °C. Blast freezed food has a solid 6 months/1 year shelf life without loss of flavour, nutritional values and weight. The opportunity to prepare in a single shot the food to be used in different times during the week enables a better work scheduling and therefore a sensible reduction in labour costs.

OPERATING MODES

Cruise: the chiller automatically sets the parameters for the quickes and best chilling (it works by probe).

Soft Chilling (Air temperature –2°C).

Hard Chilling (Air temperature –20°C).

Shock freezing (Low air temperature adjustable up to -41 ºC.)

Holding at +3°C or -18ºC (automatically activited at the end of each cycle).

All the probe-driven cycles feature ARTE (Algorithm for Remaining Time Estimation) to make planning the activities easier.

Holding at +3°C (automatically activated at the end of each cycle).

Turbo cooling: the chiller works continuously at the desired temperature. Ideal for continuous production.

It is possible to operate by time or by probe.

The control unit provides several operating settings: time/core temperature according to NF and UK regulations, time/air temperature/probe personalised according to national regulations, sterilizing cycle: UV lamps built-in (on request), 3 single sensor core temperature probes (as accessory), ideal for meats, automatic defrosting and manual defrosting. All parameters are programmable.

3-sensor core probe as standard and automatic detection of the core probe insertion.

The control unit provides two large displays to read out: time, core temperature, cycle countdown, alarms, service information.

Suitable for ambient temperatures up to 32°C.

Two specialized cycles, P1 brings down ice-cream temperature to -14°C (measured at the core when probe is inserted). Once set temperature is reacheed, the temporary maintenance phase automatically begins, holding the -14°C temperature. P2 sets temperature to -36°C / -40°C for an indefinite amount of time, maintaining the ventilation active. Temperature is adjustable up to -40°C without interrupting the cycle, allowing ice-cream to be kept longer in the freezer.

All information related to the different operating models are recorded: date, time, cycle, core temperature, holding temperature, HACCP accordance.

An audible alarm starts when the cycle ends or terminates abnormally.

Page 1
Image 1
Electrolux AOFP061C2, AOFP061CT manual Blast Chiller/Freezers 30kg 6GN1/1, Operating Modes