Electrolux B 99852G user manual Instructions for the Installer, Engineers technical data

Models: B 99852G

1 28
Download 28 pages 7.45 Kb
Page 12
Image 12

Instructions for the Installer

Instructions for the Installer

Engineers technical data

Overall dimensions

Width:

880 mm

Depth:

510 mm

Cut out dimensions

Width:

830 mm

Depth:

480 mm

Supply Connections

Gas: RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric: 230 V 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

Heat Input

 

Ultra-rapid Burner

3.8 kW Natural Gas

(Triple crown)

(12,966 BTU/HR)

 

3.8 kW L.P.G.

 

(12,966 BTU/HR)

Burner

Dia. Tap By-pass

 

1/100 mm

Auxiliary

28

Semi-rapid

32

Ultra-rapid

56

Aeration adjustment none

Semi-rapid Burner 1.9 kW (6,483 BTU/HR)

Auxiliary Burner

1.0 kW (3,412 BTU/HR)

Appliance class

 

3

Appliance category

II2H3+

Gas supply

Natural gas G 20 / 20 mbar

 

BURNER

ULTRA-RAPID

SEMI-RAPID

AUXILIARY

TYPE OF GAS

 

(triple

crown)

(medium)

(small)

 

 

 

 

 

 

 

 

POSITION

M A X

MIN

M A X

MIN

M A X

MIN

NATURAL GAS

NOMINAL THERMAL

 

 

 

 

 

 

POWER (kW)

3.8

1.20

1.9

0.45

1.0

0.33

20 mbar

NOMINAL FLOW

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

RATE (m3/h)

0.362

0.114

0.181

0.043

0.095

0.028

37.78 MJ/m3

Ws - 50.7 MJ/ m3

NOZZLE REFERENCE

146

Adjust.

96

Adjust.

70

Adjust.

 

(1/100 mm)

 

 

 

 

 

 

LPG GAS

NOMINAL THERMAL

 

 

 

 

 

 

POWER (kW)

3.8

1.20

1.9

0.45

1.0

0.33

28-30/37 mbar

NOMINAL FLOW

 

 

 

 

 

 

VALUE =

 

 

 

 

 

 

RATE (g/h)

274

86

137

32.4

72

23.8

49.92 MJ/Kg

 

NOZZLE REFERENCE

98

40

71

32

50

28

 

(1/100 mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Page 12
Image 12
Electrolux B 99852G user manual Instructions for the Installer, Engineers technical data