30" & 36" Gas
1 |
|
|
| 2 |
|
| ||
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3
4
7
5
8
6
9
To install an Electrolux ICON™ Gas
Electrolux ICON™ Downdraft Vent, cooktop power cord MUST be relocated to underside of unit.
Gas
Please have qualified electrician perform following rewiring procedure in accordance with local and national electric codes.
Tools & Materials:
10
Procedure:
1.Remove electrical access panel from rear of cooktop.
2.Disconnect power cord and ground wires, then remove from cooktop.
3.Locate area for new hole to be drilled, 1/2" in from back edge on underside of cooktop, then mark hole location using an awl or punch.
4.Use 3/4" drill bit to drill new hole completely through.
5.Route power cord wires through hole.
6.Place plastic inserts in upper and lower drilled holes to protect cord.
7.Knot power cord to secure into place.
8.Reconnect power cord and ground wires.
9.Fill remaining hole surrounding power cord with silicone caulk.
10.Cover both sides of original hole with two layers of aluminum tape.
11.Screw electrical access panel back in place.
11
USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • | High standards of quality at Electrolux Home Products, Inc. mean we are | |
constantly working to improve our products. We reserve the right to change | ||
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • | ||
specifications or discontinue models without notice. |
GC_PCRELO 03/08 | © 2008 Electrolux Home Products, Inc. | Printed in the U.S.A. |