Electrolux EGG 690 Wiring Diagram, Fault Finding, Preliminary Electrical Systems, Check, Start

Models: EGG 690

1 16
Download 16 pages 43.66 Kb
Page 11
Image 11
Wiring Diagram

Wiring Diagram

N

1

Brown

L

220 1 Fault FindingPreliminary Electrical SystemsCheckSTARTManual background

240

2

3

0

4

2

A. IGNITOR SWITCH

B. IGNITOR UNIT

Fault Finding

Preliminary Electrical Systems

removed)

 

 

 

 

 

PLUG (with cover

 

 

Check

 

 

Earth Wire

(

)

Blue

Green

START

Green/Yellow

 

 

 

 

 

 

 

 

FUSE

 

Yellow

Isolate appliance

 

 

 

 

and carry out:

 

 

 

 

 

A: Earth Continuity

Neutral Wire

 

 

 

 

check.

Blue

 

 

SOCKET

(face view)

E(Manual background)

N L

 

 

 

 

 

 

 

 

 

 

 

Blue

 

 

 

 

 

 

 

Brown

 

Green

 

 

 

 

 

 

 

 

 

 

 

Yellow

YES

 

 

Carry out:

 

Electricity supply

 

 

 

NO

Carry out:

 

 

 

 

 

 

 

 

C: Polarity check.

 

D: Resistance to

 

 

should now be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Earth check.

 

satisfactory.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Has inlet fuse blown?

NO

YES

Inlet wiring

faulty.

Rectify any

fault.

Isolate appliance and carry out:

B:Insulation check. Rectify any fault including replacing fuses as necessary.

A. EARTH CONTINUITY CHECK - Appliance must be electrically disconnected - meter set on (Ohms) x 1 scale and adjust zero if necessary.

a)Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 (Ohm), check all earth wires for continuity and all contacts are clean and tight.

B. INSULATION CHECK - Appliance electrically disconnected, all switches ON.

a)meter set on (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated - a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component. It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

11

Page 11
Image 11
Electrolux EGG 690 manual Wiring Diagram, Fault Finding, Preliminary Electrical Systems, Check, Start