8
BURNER RAPID SEMI-RAPID AUXILIARY
(large) (medium) (small)
POSITION MAX MIN MA X MIN MAX MIN MAX MIN
NOMINAL THERMAL
POWER kW 3.0 0.65 2.0 0.45 1.0 0.33 4.0 1.2
NOMINAL FLOW
RATE m3/h 0.286 0.062 0.190 0.043 0.095 0.031 0.381 0.114
NOZZLE REFERENCE 119 Adj ust. 96 Adjus t. 70 Adjust. 146 Ad just.
NOMINAL THERMAL
POWER kW 2.8 0.65 2.0 0.45 1.0 0.33 4.0 1.2
NOMINAL FLOW
RATE g/h 202 47 144 32 72 24 288 86
NOZZLE REFERENCE 86 40 71 3 2 50 28 98 56
OVERALL DIMENSIONS
Width: 680 mm.
Depth: 510 mm.
CUT OUT DIMENSIONS
Width: 560 mm.
Depth: 480 mm.
SUPPLY CONNECTIONS
Gas:
R 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
Ignition HT Spark
Spark Generator Ispra Control's BF 80066
220- 240V 0.6 VA T 120
Spark Gap Fixed
Rear Left Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (auxiliary)
Heat Input 1.0 kW (3413 BTU/HR)
Rear Right Burner (semi rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (rapid)
Heat Input 3.0 kW (10236 BTU/HR)
Central Burner (ultra-rapid triple-crown)
Heat Input 4.0 kW (13652 BTU/HR)
Burner Dia. Tap By-pass
1/100 mm
Auxiliary 28
Semi-rapid 32
Rapid 40
Ultra-rapid 56
Aeration adjustment none
NATURAL GAS
20 mbar
TYPE OF
GAS
CHARACTERISTICS
LPG GAS
28-30/37 mbar
1/100 mm
1/100 mm
VALUE = 49.92 MJ/Kg VALUE = 37.78 MJ/m3
Ws - 50.7 MJ/ m3
Instructions for the Installer

Engineers technical data

APPLIANCE CLASS : 3
APPLIANCE CATEGORY: II2H3+
APPLIANCE GAS SUPPLY: Natural gas G20 / 20mbar
ULTRA-RAPID
(triple-crown)