Electrolux EOB 21001 Instructions for the Installer, For UK use only, For Europe use only

Models: EOB 21001

1 32
Download 32 pages 33.96 Kb
Page 23
Image 23
Instructions for the Installer

electrolux 23

Instructions for the Installer

The oven is designed to be connected to 230 V (50 Hz) electricity supply.

The oven has an easily accessible terminal block which is marked as follows:

Letter L

-

Live terminal

Letter N

-

Neutral terminal

 

 

 

 

 

 

 

or E

-

Earth terminal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THIS OVEN MUST BE

EARTHED.

The cable used to connect the oven to the electrical supply must comply to the specifications given below.

For UK use only

It is necessary that you install a double pole switch between the oven and the electricity supply (mains), with a minimum gap of 3mm between the switch contacts and of a type suitable for the required load in compliance with the current rules.

The switch must not break the yellow and green earth cable at any point.

the yellow and green earth cable should be 2-3 cm longer than the other cables.

Important

After installation and connecting, the cable must be placed so that it cannot at any point reach a temperature of more than 60°C above the ambient temperature.

Before the oven is connected, check that the main fuse and the domestic installation can support the load and that the power supply is properly earthed.

The manufacturer declines any responsibility should these safety measures not be carried out.

Connection

Min. size

 

Cable/flex

 

Fuse

via

Cable/flex

 

type

 

 

 

 

 

 

 

 

 

 

 

13 A socket

2.5 mm2

 

3core

 

13 A min.

outlet

 

 

 

butyl

 

 

 

 

 

 

 

insulated

 

 

 

13 A spur box

 

 

 

 

 

 

 

 

 

 

 

 

 

Oven

2.5 mm2

 

PVC/PVC

 

15 A min.

Control

 

 

 

twin and

 

Circuit

 

 

 

earth

 

20 A max.

 

 

 

 

 

 

For Europe use only

 

 

 

 

 

 

 

Min. size Cable/

Cable / flex type

Fuse

 

flex

 

 

 

 

 

 

 

1.5 mm2

 

H07 RN-F, H05 RN-F,

13 A

 

 

 

H05 RR-F, H05 VV-F,

 

 

 

 

 

H05 V2V2-F (T90),

 

 

 

 

 

H05 BB-F

 

 

 

 

 

 

 

 

 

 

 

 

Page 23