TECHNICAL DATA
Dimension
Height
Width
Depth
Voltage
Frequency
1800 mm
595mm
650mm
230V
50Hz
The technical information are situated in the rating plate on the internal left side of the appliance and in the energy label.
Water pressure range
The water pressure must be at least 1 bar (100kPa)
Highest allowed water pressure 10 bar (1000kPa)
Consult your installer if water pressure is less than 1 bar.
If water pressure exceeds 10 bar a re- duction valve must be fitted (available from your specialist shop).
Capacity
Important!
•Do not connect the appliance in spaces where ambient temperature can de- crease to below freezing.
•The appliance may only be connected to drinking water supplies.
•The appliance may only be connected to cold water supplies.
INSTALLATION
Read the "Safety Information" carefully for your safety and correct operation of the appliance before installing the appliance.
Positioning
Install this appliance at a location where the ambient temperature corresponds to the climate class indicated on the rating plate of the appliance:
must be at least 40 mm . Ideally, however, the appliance should not be positioned be- low overhanging wall units.
The ventilation space can be:
•directly above the appliance
•behind and above the top cupboard. In this case, the space behind the top cupboard must be at least 50 mm deep.
Climate
class
SN
N
ST
T
Ambient temperature
+10°C to + 32°C +16°C to + 32°C +16°C to + 38°C +16°C to + 43°C
Location
To ensure best performance, if the appli- ance is positioned below an overhanging wall unit, the minimum distance between the top of the cabinet and the wall unit