Door open acoustic alarm

An acoustic alarm will sound when the door is left open for around 1,5 minutes. The door open alarm conditions are indicated by:

- flashing of the icon

 

;

 

Control Panel (ice dispenser)

- sounding of buzzer.

Press the key (E) to stop the acoustic alarm.

When normal conditions are restored (door closed):

- the acoustic alarm will stop.

F G K

F. Yellow indicator lamp

Lights up when the locking function has been activated.

G. Button for locking function. Used for temporary disconnection of the locking function and alarm re-setting.

H. Button for night setting/lighting. Used for activation/deactivation of the night setting function and to switch the lighting and the alarm setting on and off.

I.Lighting

J.Photo-electric sensor.

Senses prevailing lighting conditions (must not be covered).

K. Ice feeder

Activated when the paddle in the feeder is fully depressed.

H I J

Switching the ice machine on and off. The ice machine is switched on in the production plant and starts up auto- matically when the refrigerator is con- nected to water and power supplies. To switch off or on the ice machine, press in the button (D) (several times if necessary) until the corresponding icon appears . You must confirm the

choice by pressing key E within a few seconds. If the ice machine is switched off, then the cover supplied should be fitted over the ice delivery hole in the door.

Locking function - The ice dispenser control panel.

The locking function is activated in the production plant.