Induction Built-In Range
EW30IS65J S
285/16" 271/2"
Side
Overall depth including oven door in 90°open position – 451/4"
253/4"
311/2"
Front
Shave raised |
| 30"min. | 13" | ||
|
|
| |||
edge to clear |
|
|
| max. | |
space for |
|
|
|
|
|
311/2" wide | 11/2" | 24" min. clearance |
| ||
cooktop rim | max. |
| |||
|
|
| 3/8"min. with protected cabinet bottom |
| |
WALL |
|
| 30" min. for unprotected | 18" | |
Power |
| 1/2"min. | 1/2"min. | min. | |
|
|
|
|
| |
supply |
|
|
|
|
|
location |
|
| 30 ±1/16"* |
|
|
(left |
|
|
|
| |
bottom | Hatched area |
| 21 3/4"min. |
|
|
rear) |
| 22 1/8"max.** | 3 |
| |
| should be flat |
|
| 35 /4" |
|
|
|
| min. |
| |
| and leveled |
| Approx. |
| |
|
| 36 5/8" |
| ||
|
|
|
| ||
|
|
| 17/8" | max. |
|
| Locate cabinet |
| 311/2" | 24"min. | |
| doors 1" min. |
|
|
| |
13/16" | from cutout |
| (critical) |
|
|
| opening |
| 30 ±1/16"* |
|
|
| *Cabinet and countertop | **24" with optional |
|
| |
| cutout width should match | backguard installed |
|
| |
35 5/8" | Countertop |
| Locate grounded junction box |
|
|
22 7/8"min. |
| or wall outlet 8" - 17" from right |
| ||
Adjustable |
| cabinet and 2"- 4" from floor |
|
| |
23 1/4"max. |
|
|
|
| |
to |
|
|
|
| |
36 5/8" | 11/8" |
|
|
| |
|
|
|
| ||
| 21 3/4"min. |
|
|
|
|
| 22 1/8"max.** |
|
|
|
|
| Front Face of Cabinet |
|
|
|
|
30"
30" Induction Built-In Range Specifications
•Product Weight – 250 Lbs.
•Single phase 3- or
•Connected Load (kW Rating) @ 240/208 Volts = 13.2/9.9 kW
•Amps @ 240/208 Volts = 55/48 Amps
•Recommended Circuit Breaker – 50 Amps
•Always consult local and national electric codes.
•Countertop MUST be level in all directions and adjustable range
height at least 1/16" greater than tallest cabinet height, to ensure metal rangetop flange will fit properly on countertop edge.
•When installing optional Backguard Kit, cutout depth of
•Overhead cabinetry should not exceed a 13" maximum depth.
•Absolute minimum horizontal distance between overhead cabinets installed to either side of appliance must be no less than maximum width of appliance.
•Allow 24" minimum clearance between rangetop and bottom of cabinet when bottom of wood or metal cabinet is protected by not less than 1/4"
•To reduce risk of fire when using overhead cabinetry, install range hood that projects horizontally a recommended minimum of 5" beyond bottom of cabinets.
•When installing range into existing cutout depth greater than
Countertop Preparation
For detailed preparation instructions, refer to installation guide on the web.
•Flat
•Formed
•Tile countertops may need cut back 3/4" from each front corner of opening and/or rounded edge flattened.
•For existing cutout width greater than
Note: For planning purposes only. Refer to Product Installation Guide on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
•2" Rear Filler Kit: S – (PN#
•Side Panel Kit: S – (PN#
•Backguard Kit: S – (PN#
•Side Trim Kit: S – (PN#
Electrolux Major Appliances, N.A.
USA • 250 Bobby Jones Expressway • Augusta, GA 30907 • | High standards of quality at Electrolux Home Products, Inc. mean | |
we are constantly working to improve our products. We reserve the right | ||
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • | ||
to change specifications or discontinue models without notice. |
EW30IS65J 01/10 | © 2010 Electrolux Home Products, Inc. | Printed in the U.S.A. |