What to do if...

Symptom

 

Possible Cause

 

Remedy

 

 

 

 

 

Heavy build up of frost, possibly also on the door seal.

Door seal is not air tight (possibly after reversing the door).

Carefully warm the leaking sections of the door seal with a hair dryer (on a cool setting). At the same time shape the warmed door seal by hand such that it sits correctly.

The compressor does not

 

 

 

 

start immediately after

 

This is normal, no error has

 

The compressor starts after

changing the temperature

 

occurred.

 

a period of time.

setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

Switch off COOLMATIC or

 

 

 

 

FROSTMATIC manually, or

 

 

COOLMATIC or FROSTMAT-

 

wait to set the tempera-

Temperature cannot be set

 

 

ture until the function has

 

 

IC functions switched on.

 

reset automatically (refer

 

 

 

 

 

 

 

 

also to COOLMATIC/FROST-

 

 

 

 

MATIC section).

 

 

 

 

 

 

 

 

 

 

Water on the floor or on

 

Water drain hole is

 

See the “Cleaning and

storage shelves.

 

blocked.

 

Care” section.

 

 

 

 

 

Changing the light bulb

Warning! There is a risk of electric shocks! Before changing the light bulb, switch off the appliance and unplug it, or disconnect from the mains supply.

Light bulb data: 220-240 V, max. 25 W

1. To switch off, press the ON/OFF button until the mains power light extinguishes.

2.Unplug the mains plug.

3. To change the light bulb, undo the screw.

4.Press the light bulb cover as shown and slide it towards the rear of the appli- ance.

5.Change the faulty light bulb.

6.Refit the light bulb cover and the screw.

7.Put the refrigerator back into operation.