Electrical Connection
34
• The wire coloured green and yellow must be connected to the
terminal marked with the letter “E“ or by the earth symbol or
coloured green and yellow
• The wire coloured blue must be connected to the terminal “N“ or
coloured black.
• The wire coloured brown must be connected to the terminal marked
“L“ or coloured red.
• Upon completion there must not be cut, or stray strands of wire
present and the cord clamp must be secure over the outer sheath.
1
WARNING: A cut off plug inserted into a 13 amp socket is a serious
safety (shock) hazard. Ensure that the cut off plug is disposed of
safely.
Permanent connection
In the case of a permanent connection it is necessary that you install a
double pole switch between the appliance and the electricity supply
(mains), with a minimum gap of 3 mm between the switch contacts
and of a type suitable for the required load in compliance with the
current electrical regulations.
The switch must not break the yellow and green earth cable at any
point.
Positioning
To ensure correct operation:
• The appliance must be level. Use a spirit level if necessary and adjust
the feet to compensate for any unevenness in the floor.
• The surrounding area must be kept clean, free of dust and fluff.
• Do not install the appliance where the temperature may fall below
freezing or rise above 35 °C.
• Do not install the appliance on deep pile carpets or obstruct the front
ventilation grille, as this will affect the air circulation and could lead
to a build-up of heat which would adversely affect the operation of
the machine.