16 Maintenance
Daily, T4190
• Checkthatthedrumstopswhenthedoorisopened.
• Checkthatthemachinewillnotstartuntilthestartbuttonhasbeenacti-
vated.
Monthly, T4190
Dryer with RMC
Wipeoff/cleandrumandlifterswithcitricacid(Acidumcitricum).Ifsoap/sof-
tenerresidueremains,itisrecommendedalsotouseacoarsesponge.
Lackofcleaningthelifterscanreducetheautomaticresidualmoisture
controlintheclothesresultingintheclothesbeingmoisterthanrequested
whentheprogramhasended.
Quarterly, T4190
Checkthatthefollowingarenotcloggedbylintanddustorotherwise
blocked:
• Fresh-airintakeonthebackofthedryer.
• Exhaustduct.
• Fresh-airintaketotheroom(cleanasrequired,dependingontheoper-
atingfrequency).
• Checkthattheevacuationsystemconnectionaretight.
Quaterly/semi-annully, T4190
• Foroptimalfunctionofthemachine,itisimportanttocheckthelter.
• Theltermustbeunbrokenandfreeoflint.
Annually, T4190
Atleastonceayeartheinsidewearingpartsofthemachineshouldbe
checkedbyacompetent,skilledpersonandcleanedoflint.