Features

Mains switch

Controls for: modelling on/off, cell on/off, acoustic signal on/off.

Flash and modelling power control.

«X» synchro jack socket 3,5 mm.

Socket for Plug-In remote control.

Mains inlet socket and two fuses (Mains and modelling).

Locking bayonet ring for accessory and reflector fitting

Tilthead whit 5/8" - inch stand socket

Thermal safety

Halogen modelling lamp 100W, with E27 fitting, or optional alternative

*200W/GX6.35 with adaptator code 23101.

Silent fan cooling

Auto dumping function. Automatic discharge of flash power

Central umbrella tube plus external fitting

Acoustic recharging signal

Mains cable

Synchro cord of 5m (jack 3.5mm plug)

Protective cover

Total compatibility with all Elinchrom accessories

Very fast recycling time

Very short flash duration

Technical data

 

100FX

400FX

Flash power

J(Ws)

100

400

Power supply

V

200/260

200/260

F-stop, 1m, 100 ISO, with reflector 48°

 

32,5

64,5

Control range

J(Ws)

6.25-100

25-400

Recycling time (230 V)

s

0,2-0,5

0,3-1,2

Flash duration (t 0,5) 1/1

s

1/1800

1/900

(t 0,5) 1/16

s

1/1150

1/550

Modelling output

W

100

100

Voltage across sync cable

V

5

5

Connected load A/VA

(W)

6.3/1638

6.3/1638

Radio interference suppressiv CE-IEC 491

 

 

 

Dimension length x diam.

cm

21x14

21x14

Weight

kg

1,55

1,9

Tolerances and specifications conforming to IEC and CE standards. Technical data subject to change without notice.

12

Page 13
Image 13
Elinchrom 400, FX 100 manual Features, Technical data