INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTION

READ AND SAVE THESE INSTRUCTIONS

GENERAL

Carefully read the following important information regarding installation safety and main- tenance. Keep this information booklet accessible for further consultations.

The appliance has been designed for use in the ducting version (air exhaust to the outside

– Fig.1).

INSTALLATION INSTRUCTIONS

• Power Supply Connection

For connection to the power supply refer to the follows fig.8 :

BLACK

= L line

WHITE

= N neutral

GREEN /YELLOW

= G ground

A double-pole switch properly rated must be installed to provide the range hood power supply disconnection.

The appliance must be installed at a minimum height of 26 inches (66 cm) from an electric cooker stove, or 30 inches (76 cm) from gas or combined cooker stoves. If a connection ductwork composed of two parts is used, the upper part must be placed outside the lower part.Do not connect the range hood exhaust duct air to the same duct air used to exhaust hot air or fumes from other appliances other than electrical. Before proceeding with the assembly operations, remove the anti-grease filter(s) (Fig.7) so that the unit is easier to handle.

GENERAL WARNING -TO REDUCETHE RISK OF FIRE,ELECTRIC SHOCK,OR INJURY TO PERSONS,OBSERVETHE FOLLOWING:Before making electrical connections to power supply, the electrical box must be secured in place as indicated in fig.1

Before installing the appliance fix the electrical box as indicated in fig.1

-Remove the central screw fig.1A.

-Lift the electrical plant box fig. 1B.

-Remove the 3 fixed screws fig.1C.

-Position the electrical box so it is in line with the holes of the previously removed screws fig.1D and tighten.

-Pay attention that the tear tape of the electrical box is inside the slot

and then tighten screw fig.1E.

• FIXINGTO THE WALL

Drill the holes A respecting the distances indicated (Fig.3). Fix the appliance to the

wall and align it in horizontal position to the wall units. When the appliance has been adjusted, definitely fix the hood using the screws A (Fig.5). For the various installations use screws and screw anchors suited to the type of wall (e.g. reinforced concrete, plaster-

- 8 -

Page 8
Image 8
Elitair MC-I-6090 Installation Instructions Operating Instruction, General, Black, = L line, White, = N neutral