BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)

4595_FTN

PARTS LIST

ITEM NO.

PARTNO.

DESCRIPTION

 

 

 

1

100147140560

Drain Gasket

2

100322740560

Bubbler Gasket

3

101570540560

Drain Gasket

4

15005C

Regulator Retaining Nut

5

15013C

Bubbler Tube Assy.

6

170705042830

Basin

7

40048C

Button

8

40089C

Cover Nut

9 - A

400942308640

Bubbler

9 - B

98287C

Bubbler Assembly

10

40169C

Hex Nut 1-5/16-20UN

11

40250C

Tailpipe 1-1/4" x 5-3/8"

12

45476C

Drain Tube

13

50986C

Regulator Holder

14

55913C

Drain Adapter

15

55996C

In-Line Strainer

16

56092C

Poly Tubing (Cut To Length)

17

56121C

Drain Elbow 1-1/4"

18

600985551640

Drain Plug Assy.

19

61313C

Regulator

20

66346C

Drain Tube

21

70682C

Tee - 1/4

22

70683C

Union - 1/4

23

75588C

Slip Joint Nut 1-1/4"

24

75589C

Gasket

TROUBLE SHOOTING AND MAINTENANCE

Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file or small diameter wire. CAUTION: DO NOT file or cut orifice material.

Stream Regulator: If orifice is clean, regulate flow as in "STREAM HEIGHT ADJUSTMENT" instructions on page 3. If replacement is necessary, see parts list for correct regulator part number.

Actuation of Quick Connect Water Fittings: Fountain is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Fig. 5). To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4".

FIG. 5

1/4" O.D. TUBE WATER INLET TO FOUNTAIN

3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WATER SUPPLY

NOTE: WATER FLOW

DIRECTION

FIG. 6

PRINTEDINU.S.A.