ITEM | PART | DESCRIPTION | |
NO. | NO. | ||
| |||
|
|
| |
1 | 30040C | Cover - Electrical Box | |
2 | 30039C | Box - Electrical | |
3 | 31513C | Control - Cold | |
| 35882C | Control - Cold (ER21PEOY) | |
4 | 31341C | Motor - Fan | |
5 | 30824C | Fan - Blade | |
6 | 42677000 | Fan - Bracket | |
7 | 111543043890 | Nut - Hex | |
8 | 66266C | Condenser | |
9* | 35786C | Compressor Service Pak | |
10 | 36176C | Overload | |
11 | 31797C | Cover - Relay | |
12 | 19037000 | Clip - Compressor Mounting | |
13 | 101516143550 | Stud | |
14 | 100806740570 | Grommet | |
15 | 66200C | Drier | |
16 | 66505C | Evaporator Assy | |
17 | 50930C | Bumper | |
18 | 23105C | Cabinet | |
19 | 27304C | Baseplate | |
20 | 23107C | Panel - Rear (Not Shown) | |
21 | 23108C | Panel - Front | |
22 | 23109C | Panel - Condenser Mounting | |
23 | 66529C | Heat Exchanger | |
24 | 36179C | Relay | |
|
|
| |
| 220/240V 50HZ | ||
|
|
| |
ITEM | PART | DESCRIPTION | |
NO. | NO. |
| |
4 | 31395C | Motor - Fan | |
9* | 31644C | Compr. Service Pak | |
10 | 31630C | Relay | |
11 | 31632C | Cover |
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water cooler or orders for repair MUST include model number and serial number of cooler, name and part number of replacement part.
ER2-1C/2C, ER2-1PEOC, TRC2-1C
INSTALLATION
1.It is important to insure proper ventilation. For remote installation a minimum clearance of 6 inches (152 mm) to the front must be maintained, 1 inch (25 mm) each side, 3 inches (76 mm) to the rear above the unit. Wall grille
2.When unit is installed in a kitchen cabinet, two air openings with a minimum of 40 square inches each (minimum of 75% open area) must be provided in the cabinet. One opening should be in the overhang of the toe space. The other opening near the top of the cabinet. The remote unit must be installed with a minimum of 3 inch clearance between the unit and the walls of the cabinet. In addition a minimum 2 inch clearance must be provided between the toe space air opening and front of remote unit.
3.Water inlet is 1/4" (6 mm) O.D. tube. Contractor to supply connections as required.
4.Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to chiller. If flushing does not remove all particles, a water strainer should be installed in supply line.
5.Connect cooler to building supply line with a
6.Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on chiller serial plate. Never wire compressor directly to the power supply.
START-UP
1.Open supply line valve.
2.Purge air from all water lines by operating bubbler valve of fountain to which chiller is connected. Steady stream assures all air removed.
3.Rotate fan to insure proper clearance and free fan action.
4.Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set at 50°F (+/- 5°) under normal conditions. For colder water, adjust screw on item no. 3 CW.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector.
Lubrication: Motors are lifetime lubricated.
ACTUATION OF QUICK CONNECT WATER FITTINGS:
Chiller is provided with a
| 8 |
| 1, 2 |
22 |
|
| 3 |
23 | 4, 5, |
18 | 6, 7 |
| |
| 15 |
21 | 10, 11, 24 |
| 9 |
17 | 16 | 19 | 12, 13, 14 |
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620