Elkay Installation, Start-Up, Trouble Shooting & Maintenance, ERS1-1D/2D TRS1-1D/2DEWC100

Models: ERS1-1D

1 2
Download 2 pages 54.37 Kb
Page 2
Image 2
INSTALLATION

ERS1-1D/2D TRS1-1D/2D EWC100

ITEMIZED PARTS LIST

ITEM

PART NO.

 

DESCRIPTION

NO.

 

 

 

 

 

 

 

 

1

22000C

 

BRACKET - FAN MOTOR

2

23084C

 

PANEL - FRONT

3

23085C

 

ELECTRICAL COVER

4

23086C

 

PANEL - RIGHT SIDE & BACK

5

23087C

 

LEFT SIDE & TOP ASSY

6

30750C

 

COVER - TERMINAL

7

30751C

 

BALE STRAP

8

30824C

 

BLADE - FAN

9

30831C

 

RELAY

10

31513C

 

COLD CONTROL

11*

35815C

 

COMPRESSOR SERVICE PAK

12

31341C

 

MOTOR - FAN 115V

13

111543043890

 

NUT #6 HEX (FAN MOTOR MTG)

14

100806740570

 

GROMMET

15

66199C

 

DRIER

16

61521C

 

CONDENSER

17

66308C

 

HEAT EXCHANGER

18

62031C

 

DRAIN PLUG

19

66363C

 

EVAPORATOR TANK ASSY

20

101516143550

 

STUD - COMPRESSOR MOUNTING

21

19037000

 

CLIP

22

55996C

 

STRAINER

23

70683C

 

UNION 1/4 X 1/4

 

 

 

 

 

 

220/240V, 50 HZ

 

 

 

 

ITEM

PART NO.

 

DESCRIPTION

NO.

 

 

 

 

 

 

 

 

6

30583C

 

COVER - TERMINAL

7

30584C

 

BALE STRAP

9

30622C

 

RELAY

11*

31904C

 

COMPRESSOR SERVICE PAK

12

31395C

 

MOTOR - FAN

-

31407C

 

OVERLOAD/RELAY

 

 

 

 

*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINALASSEMBLY.

NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.

INSTALLATION

1.This unit is intended to be installed underneath a conventional kitchen sink, in a cabinet not less than 36" (914mm) wide (inside dimension). Two air openings with a minimum of 40" square (1016mm/square) each, minimum of 75% open area, must be provided in the cabinet. One opening must be in the overhang of the toe space. The other opening near the top of the cabinet. The remote unit must be installed with a minimum of 3" clearance between the unit and the rear wall of the cabinet. It can be installed flush against either side wall of the cabinet. The side louvers which are not against the cabinet must not be blocked by objects located within 4" (102mm) of the louvers. In addition, a minimum of 1 to 2" (25 to 51mm) clearance must be provided between the toe space air opening and front of the unit.

2.Water inlet and outlet are 1/4" (6 mm) O.D. tubes with connectors supplied.

3.Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to cooler.

4.Connect cooler to building supply line with a shut-off valve and install a 3/8" O.D. (10mm) unplated copper tube between the valve and cooler. Remove burr from outside of water line. Insert water line into fitting until it reaches a positive stop, approximately 3/4" (19mm).

5.Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor directly to the power supply.

START-UP

1.Open supply line valve.

2.Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. Steady stream assures all air is removed.

3.Rotate fan to insure proper clearance and free fan action.

4.Connect to electrical power.

TROUBLE SHOOTING & MAINTENANCE

Temperature Control: Factory set at 45°F (± 2°) under normal conditions. For colder water, adjust screw on item no. 10 in clockwise direction.

Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector.

Lubrication: Motors are lifetime lubricated.

Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4”.

5

1, 8, 12, 13

10

3

16

4

17

19

15

2

6, 7, 9, 11

14, 20, 21

18

ELKAY MANUFACTURING COMPANY - 2222 CAMDEN COURT - OAK BROOK, IL 60523 - 630.574.8484

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620