ITEMIZED PARTS LIST
ITEM | PART NO. |
| DESCRIPTION |
NO. |
| ||
|
|
| |
|
|
|
|
1 | 22000C |
| BRACKET - FAN MOTOR |
2 | 23084C |
| PANEL - FRONT |
3 | 23085C |
| ELECTRICAL COVER |
4 | 23086C |
| PANEL - RIGHT SIDE & BACK |
5 | 23087C |
| LEFT SIDE & TOP ASSY |
6 | 30750C |
| COVER - TERMINAL |
7 | 30751C |
| BALE STRAP |
8 | 30824C |
| BLADE - FAN |
9 | 30831C |
| RELAY |
10 | 31513C |
| COLD CONTROL |
11* | 35815C |
| COMPRESSOR SERVICE PAK |
12 | 31341C |
| MOTOR - FAN 115V |
13 | 111543043890 |
| NUT #6 HEX (FAN MOTOR MTG) |
14 | 100806740570 |
| GROMMET |
15 | 66199C |
| DRIER |
16 | 61521C |
| CONDENSER |
17 | 66308C |
| HEAT EXCHANGER |
18 | 62031C |
| DRAIN PLUG |
19 | 66363C |
| EVAPORATOR TANK ASSY |
20 | 101516143550 |
| STUD - COMPRESSOR MOUNTING |
21 | 19037000 |
| CLIP |
22 | 55996C |
| STRAINER |
23 | 70683C |
| UNION 1/4 X 1/4 |
|
|
|
|
|
| 220/240V, 50 HZ | |
|
|
|
|
ITEM | PART NO. |
| DESCRIPTION |
NO. |
| ||
|
|
| |
|
|
|
|
6 | 30583C |
| COVER - TERMINAL |
7 | 30584C |
| BALE STRAP |
9 | 30622C |
| RELAY |
11* | 31904C |
| COMPRESSOR SERVICE PAK |
12 | 31395C |
| MOTOR - FAN |
- | 31407C |
| OVERLOAD/RELAY |
|
|
|
|
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINALASSEMBLY.
NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
INSTALLATION
1.This unit is intended to be installed underneath a conventional kitchen sink, in a cabinet not less than 36" (914mm) wide (inside dimension). Two air openings with a minimum of 40" square (1016mm/square) each, minimum of 75% open area, must be provided in the cabinet. One opening must be in the overhang of the toe space. The other opening near the top of the cabinet. The remote unit must be installed with a minimum of 3" clearance between the unit and the rear wall of the cabinet. It can be installed flush against either side wall of the cabinet. The side louvers which are not against the cabinet must not be blocked by objects located within 4" (102mm) of the louvers. In addition, a minimum of 1 to 2" (25 to 51mm) clearance must be provided between the toe space air opening and front of the unit.
2.Water inlet and outlet are 1/4" (6 mm) O.D. tubes with connectors supplied.
3.Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to cooler.
4.Connect cooler to building supply line with a
5.Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor directly to the power supply.
START-UP
1.Open supply line valve.
2.Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. Steady stream assures all air is removed.
3.Rotate fan to insure proper clearance and free fan action.
4.Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set at 45°F (± 2°) under normal conditions. For colder water, adjust screw on item no. 10 in clockwise direction.
Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector.
Lubrication: Motors are lifetime lubricated.
Actuation of Quick Connect Water Fittings: Cooler is provided with
5 | 1, 8, 12, 13 | 10 | 3 |
16
4
17
19
15
2
6, 7, 9, 11
14, 20, 21 | 18 |