A.9.3 Digital Halls
Feature Details
Halls inputs HA, HB, HC.
Single ended inputs
Built in hysteresis for noise immunity.
Input voltage Nominal operating range: 0 V < VIn_Hall < 5 V
Maximum absolute: -1 V < VIn_Hall < 15 V
High level input voltage: VInHigh > 2.5 V
Low level input voltage: VInLow < 1 V
Input current Sink current (when input pulled to the
common): 3mA
Source current: 1.5 mA (designed to also
support open collector Halls)
Maximum frequency fMAX : 2 kHz
A.9.4 Interpolated Analog Encoder (Sine/Cosine)
Feature Details
Analog encoder format Sine and Cosine signals
Analog input signal level Offset voltage: 2.2 V – 2.8 V
Differential, 1 V peak to peak
Input resistance Differential 120
Maximum analog signal frequency fMAX : 250 kHz
Interpolation multipliers Programmable: x4 to x4096
Maximum “counts” frequency 80 mega-counts/sec “internally”
Automatic errors correction Signal amplitudes mismatch
Signal phase shift
Signal offsets
Tuba Installation Guide Technical Specifications
MAN-TUBIG (Ver. 1.3)
A-10