3
Planning Applications, LUNs, and Storage Groups
3-13
Planning File Systems and LUNs with Shared Switched Storage
LUN Details Worksheet
Storagesystem (complete this section once for each storage system)
Storage-systemnumber or name:__SS1____
Storage-system installationtype
Unshared Direct Shared-or-ClusteredDirect SharedSwitched
SPFC-AL address ID (unshared only): SPA:_____SP B:_____
SPmemory (Mbytes): SPA:_256__ SPB:_256__
Usefor caching Readcache size:_80_ MB Write cachesize: _160_ MB Cache pagesize:_2__KB
Usef or RAID 3
LUN ID:__0___
RAIDG roup ID: 0Size,GB: 72 LUN size,GB: 72 Disk IDs: SP: AB
RAID type: RAID 5 RAID 3 - Memory, MB:___ RAID1 mirrored pair RAID0
RAID1/0 Individual disk Hot spare
Caching: Readand write Write Read None
Serversthat can access this LUN: Server1
Operatingsystem information: Device name: File system, partition, or drive: T
LUN ID:__1__
RAIDG roup ID: 1 Size,GB: 72 LUN size,GB: 72 DiskIDs: SP: AB
RAID type: RAID 5 RAID3 - Memory, MB:__ _ RAID1 mirrored pair RAID0
RAID1/0 Individual disk Hot spare
Caching: Readand write Write Read None
Serversthat can access this LUN: Server1
Operatingsystem information: Device name: File system, partition, or drive: U
LUN ID:__2__
RAIDG roup ID: 2Size,GB: LUN size,GB: 18 Disk IDs: SP:AB
RAID type: RAID 5 RAID3 - Memory, MB:__ _ RAID1 mirrored pair RAID0
RAID1/0 Individual disk Hot spare
Caching: Readand write Write Read None
Serversthat can access this LUN: Server1
Operatingsystem information: Device name: File system, partition, or drive: V
X
0_0,0_1,0_2,0_3,0_4
18
X
X
X
X
1_0, 1_1
X
X
X
X
X
0_5, 0_6, 0_7, 0_8, 0_9