7 Day, 5/1/1 Day Programmable | 5/1/1 Day Programmable |
or | or |
|
|
1F83-277
• | • 7 Day, 5/1/1 Day Programmable or | |||||||||||||
|
|
|
|
|
|
|
| |||||||
Programming | Performance |
|
|
|
| Comfort & Convenience | ||||||||
Choice of 7 day or 5/1/1 day |
| Universal – Single Stage, | Optional minimum and maximum | |||||||||||
programmable or | or Heat Pump |
|
|
|
| temperature configurable | ||||||||
4 time and 4 temperature settings per | Dual Powered (Hardwire and Battery) | Auto Changeover (optional) | ||||||||||||
program (heat & cool) |
|
|
| (Patented) |
|
|
|
| Permanent program retention during | |||||
|
|
|
|
|
|
| Coded keypad lockout |
|
| |||||
Energy savings up to 33% |
|
|
|
| power loss, no batteries needed | |||||||||
Patented | Selectable Energy Management Recovery | Indefinite setpoint Hold | ||||||||||||
simplifies time and temperature |
|
| Air filter change indicator | |||||||||||
programming |
|
|
|
| Meets ENERGY STAR® specifications | |||||||||
|
|
|
|
| ||||||||||
|
|
|
|
|
|
| Simple | |||||||
Display |
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
| optional features | |||||||
|
|
|
|
|
|
|
|
|
|
|
| |||
40% larger LCD with improved contrast for | Meets California Building Code, Title 24 | |||||||||||||
Programmed temporary temperature | ||||||||||||||
easier reading |
|
|
|
|
| |||||||||
|
|
|
|
| override 4 hours max. | |||||||||
Lighted display for easier | Fast (FA) or slow (SL) heating cycle anticipation | |||||||||||||
Maintains room temperature differential | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| Compressor lockout protection (optional) | within +/- 1° | ||||||
|
|
|
|
|
|
| Setpoint temperature limits |
| Display temperature recalibration (+/- 4°) | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| Includes 2 “AA” alkaline batteries for long | |
Terminal Designations |
|
|
|
|
|
|
|
|
| battery life | ||||
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
| R | C | E/W1 W2 G Y1 | Y2 | O B | L |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
24V Hot | 24V | Heat |
| Heat | Blower/Fan | Cool | Cool | Energized | Energized | System |
| |||
Common | Relay |
| Relay | Relay | Relay |
| ||||||||
|
|
| in Cool | in Heat | Monitor |
| ||||||||
| (Optional) | (Stg. 1) | (Stg. 2) |
| (Stg. 1) | (Stg. 2) |
| |||||||
|
|
|
|
|
|
|
Dimensions
6.1"H x 3.8"W x 1.1"D
Electrical Specifications
Rating
20 to 30 VAC, 50/60 Hz or DC
0.05 to 1.0 Amp (load per terminal)
2.5 Amps maximum load (all terminals combined)
Standard Systems
Thermal Specifications
Setpoint Temperature Range: 45° to 90°F (7° to 32°C)
Rated Differential:
0.6° to 1.6°F with adjustable anticipation
Operating Ambient Temperature: 32° to 105°F (0° to 40°C)
Operating Humidity Range:
90%
Shipping Temperature Range:
Accessories
Wall Plate
Thermostat Guard
(For additional guard options refer to
For Additional Information
Visit
| Stages Heat/Cool | Programs | Model |
| Applications |
|
| Selectable Performance Features |
|
|
| Comfort & Convenience Features |
| ||||||||
| by System |
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Single | Multi- | Heat | Program | Model | Gas/Oil/ | 3 Wire | Millivolt | Thermostat |
|
| Energy | Programmable | Energy | Diplay | Alkaline |
|
| Furnace Lockout | Memory |
|
| Auto | Program | Lighted | Cool | Warranty | ||||||||||||||||
| Stage | Stage | Pump | Options | Number | Electric | Zone | Compatible | Power | Changeover | Override | Management | Fan | Star | Size | Battery Life | Display | Savings | Ignition | (Years) | |
|
|
|
|
|
|
| Valve |
| Source* |
|
| Recovery |
|
| (sq. in.) | (Years) |
|
| Module Reset |
| |
| 1/1 | 2/2 | 2/1 | 7, 5+1+1, Ø | ✓ |
| ✓ | H/B | ✓ | ✓ | ✓ |
| ✓ | 2.2 | 2+ | ✓ |
| ✓ | P | 1 | |
| 1/1 | 2/2 | 2/1 | 5+1+1, Ø | ✓ |
| ✓ | H/B | ✓ | ✓ | ✓ |
| ✓ | 2.2 | 2+ | ✓ |
| ✓ | P | 1 | |
| 1/1 | 2/2 | 2/1 | Ø | ✓ |
| ✓ | H/B | ✓ |
|
|
|
| 2.2 | 2+ | ✓ |
| ✓ | P | 1 | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
* H/B= Hardwired or Battery option |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
St. Louis, Missouri | Markham, Ontario |
The Emerson logo is a trademark and a service mark of Emerson Electric Co.