10
TROUBLESHOOTING GUIDE (CONTINUED)
A popping or cracking
sound is heard when
compressor turns on.
A bubbling or gurgling
sound is heard
(sounds like water
boiling).
Vibrations occur
when unit is on.
Moisture forms on
outside of freezer.
The lid does not
close properly.
Metal parts like the copper pipes
undergo expansion and contraction,
just like hot water pipes.
Refrigerant gas (used to cool
freezer) is circulating throughout the
system.
Check to assure that the freezer is
level.
The floor is uneven. Freezer rocks
on the floor when it is moved slightly.
The freezer is touching the wall.
Lid is slightly open.
Lid is kept open too long, or is
opened too frequently.
The lid is not sealed properly.
The lid gasket is dirty.
The storage basket is out of position
or not installed properly.
This is normal.Sound wil
disappear as freezer
continues to run.
This is normal.
Ensure freezer is level.
Level the freezer by putting
wood or metal shims under
part of the freezer.
Leave spacing between the
freezer and the wall.
See “Installation Instructions”.
Keep the lid close.
Check the lid gasket and
close lid properly.
Clean the lid gasket.
Adjust positon of storage
basket.
PROBLEM POSSIBLE CAUSE SOLUTION
TECHNICAL SPECIFICATION
Unit Dimension (WxDxH) (Inches)
Power Supply
Current
Power consumption per year
23.58” x 21.06” x 33.86”
AC 115V, 60Hz, 105W
1.3 A
212 kwh