!WARNING

Safety Instructions

To avoid fire, shock, and serious personal injury, follow all instructions carefully.

1.Read your Owner's Manual carefully before installing the light fixture. Retain Owner's Manual for future reference.

2.Be careful of the fan and blades when cleaning, painting, or working near the fan. Before installing or servicing the light fixture or ceiling fan, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.

3.Do not exceed the wattage indicated on fixture (60-watt intermediate base bulb maximum).

ADDITIONAL SAFETY INSTRUCTIONS FOR INSTALLATION

1.To avoid possible electrical shock be sure electricity is turned off at the main fuse or circuit breaker box before wiring.

2.The installation is to be in accordance with the National Electrical Code, ANSI/NFPA 70-1999 and Local Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.

3.Make certain no bare wires are exposed outside the wire connectors.

4.All wiring must conform to national and local electrical codes.

5.Follow the recommended instructions for the proper method of wiring your new light fixture. If you feel you do not have enough electrical wiring knowledge or experience, have your light fixture installed by a licensed electrician. Any electrical work not described in this manual should be performed by a licensed electrician.

WARNING: To reduce the risk of possible fire and electrical shock, install only on Emerson Model CF653, CF654, CF680, CF690, and CF695 Ceiling Fans installed in wet locations. Permissible to use this light kit on all CF and F Series Ceiling Fans installed in indoor locations. Permissible to use this light kit on CF652, CF653, CF654, CF670, CF680, CF690, CF695, CF742 and CF2000 Model Ceiling Fans installed in damp locations.

6.Carefully locate the white and blue wires (labeled either "L" or "LIGHT") in the switch cup and remove the wire connectors from the wires.

7.Insert the black and white wires from the light fitter (7) through the center hole in the switch cup (Figure 2) and thread the switch cup onto the light fitter. Hold wires taut while installing switch cup to prevent the wires from twisting.

(4) MOTOR

(2) COVER PLATE

 

CONNECTOR

 

(3) SCREWS

(5) SWITCH CUP

CONNECTOR

 

FAN SWITCH

(1) SWITCH

CHAIN

CUP

 

(6) CENTER SCREW

Figure 1

8. Insert the black and white wires through

the lockwasher (8) and hex nut (9)

(supplied). Firmly tighten the hex nut to

secure the light kit fitter to the switch

cup.

9. Connect the white wire from the switch

cup to the white wire of the light fitter

(Figure 2). Connect the blue wire from

!WARNING

To avoid possible fire or electrical shock, make certain no bare wire strands are exposed outside wire connectors.

Figure 3

10.Carefully tuck all wires and splices into the switch cup (1). (Figure 2.)

11.Connect the motor connector (4) to the switch cup connector (5).

12.Position the cup/light fitter (1)(7) on the cover plate (2) and install the three screws (3) that were previously removed in step 3 and tighten securely.

!WARNING

To avoid possible fire or electric shock, be careful not to pinch wires between switch cup and the cover plate.

Installation on Emerson Fans Having Two-Piece Die-Cast Switch Housings

Assembly and Installation

!WARNING

Do not install or use the light fixture if any part is missing or damaged. Contact your dealer for replacement.

CAUTION

To reduce the risk of electric shock, disconnect the electrical supply circuit to the fan before installing light kit.

Installation on Emerson Fans Having a Modular Switch Cup with Center Screw

1.Remove all parts and parts packages from the carton.

2.Remove and retain the four round nuts and screws securing the cage to the light fitter (Figure 4). Remove the cage and the glass globe/plate.

3.Remove the switch cup (1) from the cover plate (2) by removing the three screws (3) around the side of the switch cup (Figure 1).

4.Disconnect the motor connector (4) from the switch cup connector (5).

5.Remove the center screw (6) from the switch cup.

the switch cup to the black wire of the

light fitter. Use listed wire connectors

(6) (supplied) to make connections

(Figures 2 and 3).

(4) MOTOR

(2) COVER PLATE

 

CONNECTOR

(5) SWITCH CUP

 

BLACK WIRE

CONNECTOR

 

(6) WIRE

BLUE WIRE

CONNECTOR

 

(9) HEX NUT

WHITE WIRES

(3) SCREWS

(8) LOCKWASHER

FAN SWITCH

 

(1) SWITCH

CHAIN

 

CUP

 

 

(7) LIGHT

 

FITTER

1.Remove the cover (4) from the switch housing (1) below ceiling fan (Figure 4). Retain screws (2) for future use. Remove the center screw from the cover (4).

2.Insert the black and white wires from the light fitter (5) through the center hole in the cover (4) and thread the cover onto the light fitter and tighten. Install the spring lockwasher and hex nut.

3.Carefully pull down the white and blue wires from the switch housing and remove wire connectors.

4.Connect the white wire from the ceiling fan to the white wire of the light fitter (5). Connect the blue wire from the ceiling fan to the black wire of the light fitter. Use listed wire connectors (previously removed in step 3) to make connections. (Figures 3 and 4).

2

Figure 2

3

Page 2
Image 2
Emerson LK46 owner manual Safety Instructions