5
Analyzer and I/O-Module Expert Configuration
5 -
1
5.1
Analyzer Module Setup
-
3
5.1.1
Calibration Parameters...................................................................................
– Span gases .........................................................................................
6
– Tolerances ..........................................................................................
7
– Calibration procedure setup ................................................................
9
– Time controlled calibration ..................................................................
-12
– Calibration...........................................................................................
-15
– Advanced calibration methods ............................................................
-18
– Zero gases ..........................................................................................
-20
5.1.2
Alarm Parameters...........................................................................................
-21
5.1.3
Range Parameters .........................................................................................
-25
– Begin and end of ranges.....................................................................
-27
– Response times (t90) ...........................................................................
-28
– Autoranging control .............................................................................
-29
5.1.4
Cross Interference Compensation..................................................................
-31
5.1.5
Linearization ...................................................................................................
-33
5.1.6
Programmable Logic Control (PLC)................................................................
-37
5.1.7
Programmable Calculator ...............................................................................
-45
5.1.8
Measurement Display Configuration...............................................................
-49
5.1.9
Acknowledgement of Status Reports..............................................................
-52
5.1.10
Concentration Measurement Parameters.......................................................
-54
5.1.11
Peak Measurement ........................................................................................
-55
5.1.12
Differential Measurement ...............................................................................
-57
5.1.13
Gasflow Setup ................................................................................................
-59
5.1.14
Pressure Compensation .................................................................................
-60
5.1.15
Flow Measurement .........................................................................................
-62
5.1.16
Temperature Measurement ............................................................................
-63
5.1.17
Loading/Saving Configuration Parameters .....................................................
-64
5.1.18
Inputs and Outputs .........................................................................................
-67
– Local SIO ............................................................................................
-68
– Local DIO ............................................................................................
-74
– Signal codes........................................................................................
-75
5.1.19
Delay and Average .........................................................................................
-79
5.1.20
Special Functions ...........................................................................................
-81
5.1.21
AK-Protocol Communication ..........................................................................
-82
II
NGA 2000
90003482(2) [NGA-e (MLT-Software 3.2.X)] 07/98