Emerson Packaged Drives and Engineered Systems manual 325

Models: Packaged Drives and Engineered Systems

1 24
Download 24 pages 29.06 Kb
Page 8
Image 8

www.emersonct.com

800-533-0031

AC RapidPak Order Code Configurator

 

 

Order String

R

x

xxx

x

xxx

x x x - xxxxx

 

Product

 

 

 

 

 

Additional Options (if required)

R = RapidPak

 

 

 

 

 

1 = AC Input Reactor

Enclosure Style

 

 

 

 

 

2 = AC Output Reactor

 

 

 

 

 

4 = Auto 3-Contactor Bypass

S = Slimline2

 

 

 

 

 

5 = Blower Motor Starter

C = Cube1

 

 

 

 

 

A = Manual Three-Contactor Bypass

Drive Model

 

 

 

 

 

F = NEMA-3R Enclosure

 

 

 

 

 

 

SKN = SK Normal Duty

 

 

 

 

Input Power

SKH = SK Heavy Duty

 

 

 

 

 

CGN = GP20 Normal Duty

 

 

 

 

0 = Main Lugs with Input Fusing

CGH = GP20 Heavy Duty

 

 

 

 

1 = Thru-Door Disconnect C/B

SPN = SP Normal Duty

 

 

 

 

 

2 = Thru-Door Disconnect Switch

SPH = SP Heavy Duty

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Keypad

Voltage Rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N = Keypad on Drive

8

= 208

V / 3 / 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K = Keypad on Door

2

= 230

V / 3

/ 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

= 380

V / 3

/ 60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Door Mounted Operator Station3

4

= 460

V / 3

/ 60

 

 

 

 

 

 

 

 

 

 

 

 

0

= Blank

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Horsepower

 

 

 

 

 

 

 

1

= Stop PB, Start PB, Fault Light, Pot

see Order Code tables

 

 

 

 

 

2

= #1 + JOG PB, Fwd/Rev SS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

= #2 + Power On Light

1 Cube Enclosure Style does not allow for additional options (insufficient space)

4

= HOA SS, Power On, VFD Run, Fault Light, Pot

2 Smallest Slimline Enclosure Style allows all the options unless bypass is selected,

5

= HOA SS plus Bypass

then there is a limit of either an input or output reactor.

3 Abbreviation Key: PB = Push button; SS = Selector Switch; HOA = Hand-Off-Auto

 

 

 

 

Order string: The base Order Code requires a minimum of 12 characters in sequence to create the order string.

Additional Order Code

AC Input Reactor

3% impedance input line reactor. Reduces harmonics to line. Slimline only

 

 

AC Output Reactor

3% impedance output line reactor. Increases motor insulation life by reducing dV/dt. Slimline only

 

 

Auto Three-Contactor Bypass

Used in applications where full speed operation is required if drive becomes inoperable. Automatically switches

 

upon drive fault. Requires Operator Station #5. Slimline only

 

 

Blower Motor Starter

Controls separately powered motor blower on TEBC and DPFV motors used for wide speed range applications.

 

Not available with Bypass Options. Slimline only

 

 

Manual Three-Contactor Bypass

Used in applications where full speed operation is required if drive becomes inoperable. Manual (operator)

 

activated via Operator Station #5. Slimline only

 

 

Nema 3R Enclosure

Enclosure intended for outdoor use. Provides a degree of protection against falling rain, sleet, and external ice.

 

 

For options not included in the Order Code configurator, please consult factory.

AC RapidPak

325

Page 8