www.emersonct.com
AC RapidPak Order Code Configurator |
|
| ||||
Order String | R | x | xxx | x | xxx | x x x - xxxxx |
| ||||||
Product |
|
|
|
|
| Additional Options (if required) |
R = RapidPak |
|
|
|
|
| 1 = AC Input Reactor |
Enclosure Style |
|
|
|
|
| 2 = AC Output Reactor |
|
|
|
|
| 4 = Auto | |
S = Slimline2 |
|
|
|
|
| 5 = Blower Motor Starter |
C = Cube1 |
|
|
|
|
| A = Manual |
Drive Model |
|
|
|
|
| F = |
|
|
|
|
|
| |
SKN = SK Normal Duty |
|
|
|
| Input Power | |
SKH = SK Heavy Duty |
|
|
|
|
| |
CGN = GP20 Normal Duty |
|
|
|
| 0 = Main Lugs with Input Fusing | |
CGH = GP20 Heavy Duty |
|
|
|
| 1 = | |
SPN = SP Normal Duty |
|
|
|
|
| 2 = |
SPH = SP Heavy Duty |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Keypad | |
Voltage Rating |
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| N = Keypad on Drive | |||||
8 | = 208 | V / 3 / 60 |
|
|
|
|
|
|
| |||
|
|
|
|
|
|
| K = Keypad on Door | |||||
2 | = 230 | V / 3 | / 60 |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
| |||||
3 | = 380 | V / 3 | / 60 |
|
|
|
|
|
|
|
| |
|
|
|
|
|
| Door Mounted Operator Station3 | ||||||
4 | = 460 | V / 3 | / 60 |
|
|
|
|
|
| |||
|
|
|
|
|
| 0 | = Blank | |||||
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| |||
Horsepower |
|
|
|
|
|
|
| 1 | = Stop PB, Start PB, Fault Light, Pot | |||
see Order Code tables |
|
|
|
|
| 2 | = #1 + JOG PB, Fwd/Rev SS | |||||
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
| 3 | = #2 + Power On Light | |
1 Cube Enclosure Style does not allow for additional options (insufficient space) | ||||||||||||
4 | = HOA SS, Power On, VFD Run, Fault Light, Pot | |||||||||||
2 Smallest Slimline Enclosure Style allows all the options unless bypass is selected, | ||||||||||||
5 | = HOA SS plus Bypass | |||||||||||
then there is a limit of either an input or output reactor. | ||||||||||||
3 Abbreviation Key: PB = Push button; SS = Selector Switch; HOA = |
|
| ||||||||||
|
|
Order string: The base Order Code requires a minimum of 12 characters in sequence to create the order string.
Additional Order Code
AC Input Reactor | 3% impedance input line reactor. Reduces harmonics to line. Slimline only |
|
|
AC Output Reactor | 3% impedance output line reactor. Increases motor insulation life by reducing dV/dt. Slimline only |
|
|
Auto | Used in applications where full speed operation is required if drive becomes inoperable. Automatically switches |
| upon drive fault. Requires Operator Station #5. Slimline only |
|
|
Blower Motor Starter | Controls separately powered motor blower on TEBC and DPFV motors used for wide speed range applications. |
| Not available with Bypass Options. Slimline only |
|
|
Manual | Used in applications where full speed operation is required if drive becomes inoperable. Manual (operator) |
| activated via Operator Station #5. Slimline only |
|
|
Nema 3R Enclosure | Enclosure intended for outdoor use. Provides a degree of protection against falling rain, sleet, and external ice. |
|
|
For options not included in the Order Code configurator, please consult factory.
AC RapidPak