FEATURES
Indicators
Each Liebert PSS has a visual SURGE PROTECTION indicator that illuminates (green) to show that the surge suppressor is functioning properly.
The Liebert PSS also has an audible alarm to alert you if the suppression fails. Surge suppressors are often hidden from view behind furniture and other objects that prevent you from seeing the visual indicator.
Wall Mounting
If wall mounting is desired, two keyed slots are provided and located on the back of the surge suppressor.
Wall Mounting Detail
Rear View
TROUBLESHOOTING
If the Liebert PSS malfunctions during operation, check the following chart for proper adjustment. For further assistance, please contact your local Emerson Network Power representative.
Problem | Recommended Actions | |
|
| |
The green | Try plugging the Liebert PSS into a different wall receptacle. | |
GROUND | • If the indicator illuminates, the Liebert PSS is operating properly and the first wall receptacle needs repair. Please | |
indicator | contact an electrician to repair the faulty receptacle. | |
does not | • If the indicator does NOT illuminate in a different receptacle: | |
illuminate. | ||
• Your building wiring might not contain a ground conductor. In this case, the indicator light will not illuminate but | ||
| ||
| you will still have power out of the Liebert PSS. | |
| • The Liebert PSS may have been damaged. Please contact your supplier for any warranty return/repair | |
| instructions. | |
The green | Try plugging the Liebert PSS into a different wall receptacle. | |
SURGE | • If the indicator illuminates, the Liebert PSS is operating properly and the first wall receptacle needs repair. Please | |
PROTECTION | contact an electrician to repair the faulty receptacle. | |
indicator | • If the indicator does NOT illuminate in a different receptacle: | |
does not | ||
• The Liebert PSS may have been overloaded and the internal circuit breaker may have tripped. Remove all | ||
illuminate | ||
when | loads from device and reset the circuit breaker by pushing the button back in. Replace loads one at a time. | |
powered ON. | • The Liebert PSS may have been damaged. Please contact your supplier for any warranty return/repair | |
| instructions. |
SPECIFICATIONS
Model Number | PRF 1080 |
| NET 1080T |
|
|
|
|
AC Power Protection |
|
|
|
Nominal Operating Voltage |
| 120V | |
|
|
| |
Maximum Operating Voltage |
| 130V | |
|
|
| |
Rated Output |
| 15A | |
|
| ||
Mode of Protection | |||
|
| ||
Peak Surge Rating | 72,000A | ||
|
| ||
Surge Energy | 1080 Joules | ||
|
|
| |
EMI/RFI Filtration |
| Yes | |
|
|
| |
UL 1449 Surge Voltage Rating |
| 330V | |
|
|
|
|
Network Protection |
|
|
|
Connection Type | — |
| RJ45 |
|
|
|
|
Protection | — |
| 2 Pair |
|
|
|
|
© 2008 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.
®Liebert is a registered trademark of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners.
IO-22002_REV0_07-08
Technical Support / Service | United States |
1050 Dearborn Drive | |
(Outside U.S. | P.O. Box 29186 |
upstech@emersonnetworkpower.com | Columbus, OH 43229 |
Web site: www.liebert.com |
|