Specifications

Specifications

Liebert XDP-W Coolant Distribution Unit

Nominal Capacity

100 kW

Input Voltage

460 V, 3 ph, 60 Hz

 

400 V, 3 ph, 50 Hz

 

208 V, 3 ph, 60 Hz

Full load amps

4.3A @ 400V

 

2.5A @ 460V

 

 

Height, unit only

78” (1981 mm)

Width

38” (965 mm)

Depth

35” (889 mm)

Weight, unit only

750 lbs (340 kg)

Liebert Corporation

1050 Dearborn Drive

P.O. Box 29186

Columbus, Ohio 43229

800 877 9222 Phone (U.S. &

Canada Only)

614 888 0246 Phone (Outside U.S.)

614 841 6022 FAX

Via Leonardo Da Vinci 8

Zona Industriale Tognana

35028 Piove Di Sacco (PD)

Italy

39 049 9719 111 Phone

39 049 5841 257 FAX

Emerson Network Power Asia Pacific

7/F., Dah Sing Financial Centre

108 Gloucester Rd, Wanchai

Hong Kong

852 25722201 Phone

852 28029250 FAX

liebert.com

Liebert XDP-W units supporting

Liebert XDR-W units

Hydraulic Schematic

 

XDP-W

 

 

 

 

 

 

 

BUILDING

 

 

 

DUAL

 

 

 

 

 

CHILLED

 

 

 

PUMPS

 

WATER

 

 

 

 

 

LOOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEAT

EXCHANGER

2-WAY VALVE CONTROLS SECONDARY FLUID ABOVE ROOM DEWPOINT

Low pressure water circuit with a fluid temperature always above the actual dewpoint, to prevent condensation.

XDR-W modules or XDK-W enclosures

24 x 7 Tech Support

800 222 5877 Phone

614 841 6755 (outside U.S.)

While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

© 2007 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.

All names referred to are trademarks or registered trademarks of their respective owners.

®Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.

SL-16900 (R10/07) Printed in USA

Emerson Network Power.

The global leader in enabling

Business-Critical Continuity.

Liebert XDP-W Coolant Distribution Unit AC Power

Liebert Corporation Connectivity

liebert.com DC Power 24 x 7 Tech Support Embedded Computing

Emerson Network Power. Embedded Power

Business-Critical Continuity™. Monitoring

 Precision Cooling Outside Plant

Emerson Network Power.com Power Switching & Controls

Manual background Precision Cooling

Manual background Racks & Integrated Cabinets Manual background Services

Manual background Surge Protection

Emerson Network Power.com

Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.

Page 2
Image 2
Emerson Specifications, Liebert XDP-W Coolant Distribution Unit, Liebert Corporation, liebert.com, 24 x 7 Tech Support