Instruction

51.LF:IM

Baumann51000 Series Instructions

April 2007

bonnet - confirm correct orientation - then secure with hex nuts (7). DO NOT TIGHTEN AT THIS

POINT.

6.Install stem guide (8) and packing kit (9) on the plug stem (4) in the proper order as shown in figure 3, page 6.

7.Carefully press into top of bonnet (6) making sure each part is seated properly.

8.Install packing rings over the stem one at a time. Use the packing follower nut (11) to push each packing ring in individually to avoid jamming.

9.With all required packing (9) in place, tighten the packing follower nut (11) until it becomes stiff. DO NOT OVERTIGHTEN THE PACKING

FOLLOWER (11).

10.Now tighten hex nuts (7).

Table 2. 51000 PLUG SELECTION

KEY NO.

VALVE

SIZE

PLUG Cv

PART NUMBER

ASTM A479 S21800 ANNEALED

PART NUMBER

N10276 NICKEL ALLOY

MARKING

CODE

4

Linear

0.5 inch

2.5

51425-411-999

51425-1-411-999

T01

1.5

51415-411-999

51415-1-411-999

T02

ONLY

1.0

51410-411-999

51410-1-411-999

T03

 

 

0.45

51402-4

51402-4-1

T04

 

0.2

51402-3

51402-3-1

T05

 

0.1

51401-12

51402-2-1

T06

 

0.06

51401-11

51041-11-1

T07

0.25

0.03

51401-10

51401-10-1

T08

&

0.015

51401-9

51401-9-1

T09

0.008

51401-8

51401-8-1

T10

 

0.50

0.004

51401-7

51401-7-1

T11

inch

0.002

51401-6

51401-6-1

T12

0.001

51401-5

51401-5-1

T13

 

 

0.0005

51401-4

51401-4-1

T14

 

0.00025

51401-3

51401-3-1

T15

 

0.00013

51401-2

51401-2-1

T16

 

0.5

51402-5

51402-5-1

T17

 

 

 

 

 

MATERIAL CODES: (Stamped on Plugs) B = Nitronic 60;

C = N10276 Nickel Alloy;

A = Stainless Steel (S31600)

5

Page 5
Image 5
Emerson Process Management 51000 instruction manual Point, Follower, Plug Selection, Valve Size, Plug Cv