Instruction
51.LF:IM | Baumann™ 51000 Series Instructions |
April 2007 |
bonnet - confirm correct orientation - then secure with hex nuts (7). DO NOT TIGHTEN AT THIS
POINT.
6.Install stem guide (8) and packing kit (9) on the plug stem (4) in the proper order as shown in figure 3, page 6.
7.Carefully press into top of bonnet (6) making sure each part is seated properly.
8.Install packing rings over the stem one at a time. Use the packing follower nut (11) to push each packing ring in individually to avoid jamming.
9.With all required packing (9) in place, tighten the packing follower nut (11) until it becomes stiff. DO NOT OVERTIGHTEN THE PACKING
FOLLOWER (11).
10.Now tighten hex nuts (7).
Table 2. 51000 PLUG SELECTION
KEY NO.
VALVE
SIZE
PLUG Cv
PART NUMBER
ASTM A479 S21800 ANNEALED
PART NUMBER
N10276 NICKEL ALLOY
MARKING
CODE
4
Linear
0.5 inch | 2.5 | T01 | |||
1.5 | T02 | ||||
ONLY | |||||
1.0 | T03 | ||||
| |||||
| 0.45 | T04 | |||
| 0.2 | T05 | |||
| 0.1 | T06 | |||
| 0.06 | T07 | |||
0.25 | 0.03 | T08 | |||
& | 0.015 | T09 | |||
0.008 | T10 | ||||
| |||||
0.50 | 0.004 | T11 | |||
inch | 0.002 | T12 | |||
0.001 | T13 | ||||
| |||||
| 0.0005 | T14 | |||
| 0.00025 | T15 | |||
| 0.00013 | T16 | |||
| 0.5 | T17 | |||
|
|
|
|
|
MATERIAL CODES: (Stamped on Plugs) B = Nitronic 60;
C = N10276 Nickel Alloy;
A = Stainless Steel (S31600)
5