EMI S1C 30-36 S1C/S1H Specifications for System options, Cooling Systems with Wall Units, or or

Models: S1C 9-24 S1C 30-36

1 4
Download 4 pages 13.16 Kb
Page 4
Image 4
S1C/S1H Specifications for System options

S1C/S1H Specifications for System options

NOTE: All EMI products are subject to ongoing development. Design and specifications may change without notice.

System Performance Data: Matched with EMI AmericaSeries indoor units

or  oror

CAC/CAH

or Heat pumps System Options with Wall Units or

WLC/wlh

S1C/S1H Single ZoneUNC/UNh

Heat pumps System Options with Wall Units

Condenser

Wall Unit

Cooling Btuh

Heating Btuh

SEER

HSPF

SHR

EER

COP

Ref.

S1H9

WLH09

9,000

8,600

13.0

8.0

.75

11.6

3.6

R22

S1H2

WLH12

11,400

10,600

13.0

8.0

.73

11.5

3.4

R22

S1H8

WLH24

18,000

16,400

13.0

7.7

.73

12.1

3.8

R22

S1H4

WLH24

23,000

20,600

13.0

8.3

.71

11.9

3.5

R22

Heat pumps System Options with UNIVERSAL Units

Condenser

Universal

Cooling Btuh

Heating Btuh

SEER

HSPF

SHR

EER

COP

Ref.

S1H9

UNH09

8,800

7,800

13.0

7.7

.75

11.6

3.4

R22

S1H2

UNH12

11,600

10,200

13.0

7.7

.73

11.5

3.5

R22

S1H8

UNH24

18,000

16,400

13.0

7.7

.73

12.1

3.8

R22

S1H4

UNH24

23,000

20,600

13.0

8.3

.71

11.9

3.5

R22

Heat pumps System Options with Cassette Units

Condenser

Cassette

Cooling Btuh

Heating Btuh

SEER

HSPF

SHR

EER

COP

Ref.

S1H9

CAH12

9,300

8,000

13.0

7.7

.80

12.4

3.3

R22

S1H2

CAH12

11,800

10,800

13.0

7.7

.72

11.4

3.4

R22

S1H8

CAH24

18,200

15,000

13.0

7.7

.78

12.3

3.3

R22

S1H4

CAH24

24,000

20,000

13.0

7.7

.69

11.7

3.3

R22

Cooling Systems with Wall Units

Condenser Wall Unit Btuh SEER SHR EER Ref.

S1C9 WLH09 9,000 13.0 .79 11.8 R22

S1C2 WLH12 12,000 13.0 .74 12.9 R22

* S1C8 WLH24 18,000 14.0 .78 13.0 R22

S1C4 WLH24 24,000 13.0 .70 12.5 R22

S1C3 WLC36 30,000 13.0 .72 12.6 R22

S1C6 WLC36 33,600 13.0 .69 12.1 R22

Cooling Systems with Cassette Units

Condenser Cassette Btuh SEER SHR EER Ref.

S1C9 CAH12 9,000 13.0 .79 11.7 R22

S1C2 CAH12 12,000 13.0 .72 12.2 R22

S1C8 CAH24 18,000 13.0 .76 12.3 R22

S1C4 CAH24 23,000 13.0 .67 11.8 R22

* S1C3 CAC36 30,000 14.0 .82 12.0 R22

S1C6 CAC36 36,000 13.0 .74 12.6 R22

*Important - This system has been designed and manufactured to meet ENERGY

STAR criteria for energy efficiency. However, proper refrigerant charge and proper air flow are critical to achieve rated capacity and efficiency.

Installation of this product should follow the manufacturer’s refrigerant charging and air flow instructions. Failure to confirm proper charge and airflow may reduce energy efficiency and shorten equipment life.

Phone: 1-800-228-9364

5780 Success Drive,

Fax: 1-800-232-9364

Rome, NY 13440

Page 4
Image 4
EMI S1C 30-36, S1C 9-24 S1C/S1H Specifications for System options, Heat pumps System Options with Wall Units, or or