IMPORTANT SAFETY INFORMATION
THIS IS A HEATING APPLIANCE
DO NOT OPERATE THIS APPLIANCE WITHOUT FRONT PANEL INSTALLED.
• | An unvented room heater having an input rating of | SERVICE PERSON. The appliance should be inspected | ||
| more than 6,000 Btu per hour shall not be installed in a | before use and at least annually by a professional service | ||
| bathroom. | person. More frequent cleaning may be required due to | ||
• An unvented room heater having an input rating of more | excessive lint from carpeting, bedding materials, etc. It | |||
is imperative that control compartments, burners and | ||||
| than 10,000 Btu perhourshall not be installed in a bedroom | |||
| circulating | air passageways of the appliance be kept | ||
| or bathroom. | |||
| clean. |
| ||
• | Due to high temperatures, the appliance should be located |
| ||
• DO NOT use this room heater if any part has been under | ||||
| out of traffic and away from furniture and draperies. | |||
| water. Immediately call a qualified service technician | |||
• Children and adults should be alerted to the hazard of | ||||
to inspect the room heater and to replace any part of the | ||||
| high surface temperature and should stay away to avoid | |||
| control system and any gas control which has been under | |||
| burns or clothing ignition. | |||
| water. |
| ||
• Young children should be carefully supervised when they |
| |||
• Keep appliance area clear and free from combustible | ||||
| are in the same room with the appliance. | |||
| materials, | gasoline and other flammable vapors and | ||
• Do not place clothing or other flammable material on or | ||||
liquids. |
| |||
| near the appliance. | • WARNING: ANY CHANGE TO THIS HEATER OR ITS | ||
• Due to high surface temperatures, keep children, clothing | ||||
CONTROLS CAN BE DANGEROUS. | ||||
| and furniture away. | Any safety screen or guard removed for servicing an | ||
• WARNING: Do not use a blower insert, heat exchanger | ||||
appliance must be replaced prior to operating the heater. | ||||
| insert or other accessory not approved for use with | • WARNING: Failure to keep the primary air opening(s) | ||
| heater. | |||
| of the burner(s) clean may result in sooting and property | |||
• Installation and repair should be done by a QUALIFIED | ||||
damage. |
| |||
|
|
|
|
WARNING
When used without adequate combustion and ventilation air, |
| CARBON MONOXIDE POISONING MAY LEAD TO |
heater may give off CARBON MONOXIDE, an odorless, poi- |
| DEATH. |
sonous gas. |
| Early signs of carbon monoxide poisoning resemble the flu, with |
|
| |
|
| |
Do not install heater until all necessary provisions are made |
| headache, dizziness and/or nausea. If you have these signs, heater |
for combustion and ventilation air. Consult the written in- |
| may not be working properly. Get fresh air at once! Have heater |
structions provided with the heater for information concerning |
| serviced. |
combustion and ventilation air. In the absence of instructions, |
| Some people — pregnant women, persons with heart or lung dis- |
refer to the National Fuel Gas Code, ANSI Z223.1, Section |
| ease, anemia, those under the influence of alcohol , those at high |
5.3 or applicable local codes. |
| altitudes — are more affected by carbon monoxide than others. |
This heater is equipped with a PILOT LIGHT SAFETY SYS- |
| The pilot light safety system senses the depletion of oxygen at |
TEM designed to turn off the heater if not enough fresh air is |
| its location. If this heater is installed in a structure having a high |
available. |
| vertical dimension, the possibility exists that the oxygen supply |
|
| at the higher levels will be less than that at the heater. In this type |
DO NOT TAMPER WITH PILOT LIGHT SAFETY |
| of application, a fan to circulate the structure air will minimize |
SYSTEM! |
| this effect. The use of this fan will also improve the comfort level |
If heater shuts off, do not relight until you provide fresh air. |
| in the structure. When a fan is used to circulate air, it should be |
| located so that the air flow is not directed at the burner. | |
If heater keeps shutting off, have it serviced. Keep burner and |
| |
|
| |
control compartment clean. |
|
|
Page 3 |