Page 10 19563-1-0706
Figure 4
Installing Wall Bracket (Figures 5 and 6)
After finding a location for the furnace, gas supply and vent, the
wall bracket must be positioned and installed. The bracket should
be mounted to the wall studs, if possible, or anchored solidly to
the wall. Use the (2) 10 x 1 1/2" (38mm) hex-head screws or (2)
plastic anchors provided. Drill (2) 5/16" (8mm) diameter holes
in wall if plastic anchors are used. Attach the two wall mounting
brackets to the casing back by using (4) 10 x 1/2" (13mm) hex-
head screws provided.
Figure 5
Figure 6
Figure 7
Figure 8
2"(51mm) TO 13" (330mm)
2"(51mm) TO 32" (813mm)
WALL
CASING
BACK
#10X 1"
WALLMOUNTING BRACKET
WALL
BRACKET
#10X 1/2"
#10X 1/2"
4"(102mm)
WALL
INTAKEFLEX HOSE
WITHCLAMPS
EXHAUST
INTAKEAIR
MOUNTINGPLATE
EXHAUSTELBOW MAY
BECUT TO LENGTH
TOFIT VENT BOX.
SECUREIN PLACE
USINGHOSE CLAMPS
PROVIDED.
KEEPCAP ON
UN-USEDAIR
INTAKEOPENING