Empire Comfort Systems VFSM-30-3 installation instructions Important Safety Information

Models: VFSM-30-3

1 24
Download 24 pages 63.01 Kb
Page 3
Image 3
IMPORTANT SAFETY INFORMATION

IMPORTANT SAFETY INFORMATION

An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bath- room

An unvented room heater having an input rating of more than 10,000 Btu per hour shall not be installed in a bedroom or bathroom.

Never burn solid fuels in a fireplace where a gas log set is installed.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance.

Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition.

Young children should be carefully supervised when they are in the same room as the appliance.

This unit complies with ANSI Z21.11.2 Unvented Heaters and it also complies with ANSI Z21.60 Decorative Vented Appliances for Solid Fuel Burning Fireplaces. State or local codes may only allow operation of this appliance in a vented configuration. Check your state or local codes.

Correct installation of logs, proper location of the heater and annual cleaning are necessary to avoid potential problems with sooting. Sooting, resulting from improper installation or operation, can settle on surfaces outside the fireplace.

Avoid any drafts that could alter burner flame patterns. Do not allow fans to blow directly into the fireplace. Do not place a blower inside burn box area of firebox. Ceiling fans may create drafts that alter burner flame patterns. Sooting and improper burning will occur as a result of drafts.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blowerinsert, heat exchangerinsert or other accessory not approved for use with this heater.

Periodic examination and cleaning of the venting system of the solid-fuel burning fireplace, including frequency of such examination and cleaning, by a qualified agency.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/NFPA54.

NOTE: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that the control compartment, burners and circulating air passageways of the appliance be kept clean.

Any safety screen or guard removed for servicing an ap- pliance must be replaced prior to operating the appliance. Provide adequate combustion and ventilation air.

The flow of combustion and ventilation air MUST NOT be obstructed.

Provide adequate clearances around air openings into the combustion chamber and adequate accessibility clearance for servicing and proper operation. NEVER obstruct the front opening of the appliance.

An unvented room heater intended for installation in a solid-fuel burning fireplace shall comply with the following instructions.

A fireplace screen must be in place when the appliance is operating and, unless otherprovisions forcombustion airare provided, the screen shall have an opening(s) forintroduction of combustion air.

Solid-fuels shall not be burned in a masonry or UL 127 factory-built fireplace in which an unvented room heater is installed.

Any glass doors shall be fully opened when the appliance is in operation.

Any outside air ducts and/or ash dumps in the fireplace shall be permanently closed at time of appliance installation.

WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.

WARNING:Beforeinstallinginasolid-fuelburningfireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

WARNING

CARBON MONOXIDE POISONING MAY LEAD TO

DEATH.

When used without adequate combustion and ventilation air,

 

Early signs of carbon monoxide poisoning resemble the flu,

heater may give off CARBON MONOXIDE, an odorless,

poisonous gas.

with headache, dizziness and/or nausea. If you have these

 

 

signs, heater may not be working properly. Get fresh air at

Do not install heater until all necessary provisions are made

 

for combustion and ventilation air. Consult the written

 

once! Have heater serviced.

instructions provided with the heater for information

 

Some people – pregnant women, persons with heart or lung

concerning combustion and ventilation air. In the absence

 

disease, anemia, those under the influence of alcohol, those

of instructions, refer to the National Fuel Gas Code, ANSI

 

at high altitudes – are more affected by carbon monoxide

Z223.1, Section 5.3 or applicable local codes.

 

than others.

 

 

The pilot light safety system senses the depletion of oxygen at

This heater is equipped with a PILOT LIGHT SAFETY

its location. If this heater is installed in a structure having a

SYSTEM designed to turn off the heater if not enough fresh

high vertical dimension, the possibility exists that the oxygen

air is available.

supply at the higher levels will be less than that at the heater.

DO NOT TAMPER WITH PILOT LIGHT SAFETY

 

 

In this type of application, a fan to circulate the structure air

SYSTEM!

 

 

will minimize this effect. The use of this fan will also improve

If heater shuts off, do not relight until you provide fresh air.

the comfort level in the structure. When a fan is used to

If heater keeps shutting off, have it serviced. Keep burner and

circulate air, it should be located so that the air flow is not

control compartment clean.

directed at the burner.