VENT SAFETY SHUTOFF SYSTEM

This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system.

Warning:

Operation of this heater, when not connected to a properly installed and maintained venting system or tampering with the vent safety shutoff system, can result in carbon monoxide (CO) poisoning and possible death.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

This room heater is equipped with a vent safety switch. The vent safety switch will cause gas flow to the pilot to “shut off” due to improper venting or a blocked flue.

If the vent safety switch continues to “shut off” the gas flow to the pilot, a qualified service person must be contacted to inspect for improper venting, blockage in the vent pipe or the vent safety switch for being defective.

REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER

This room heater has a reversible draft diverter. The draft diverter is installed in the vertical position at the factory. Please use the following steps to change the draft diverter from the vertical positing to the horizontal position.

1.Remove L280 vent safety switch from the draft diverter.

2.Inside your yellow instruction envelope will be a 1 1/2” x 2 1/4” (38mm x 51mm) vent safety switch hole cover plate and two (2) 1/2” screws for attachment of vent safety switch hole cover plate to the draft diverter. Attach vent safety switch hole cover plate over hole on the draft diverter from which the L280 vent safety switch was removed.

3.Remove two (2) screws at bottom of draft diverter and lift upward to remove draft diverter from the draft diverter plate. Rotate draft diverter into the horizontal position and slide back into the draft diverter plate. Attach two (2) screws into bottom of the drafter diverter.

4.Remove vent safety switch hole knockout and two (2) knockouts for screws on opposite side of draft diverter.

5.

Attach L280 vent safety switch to the draft diverter.

 

6.

Repositioning of the draft diverter is completed.

DRAFT DIVERTER CAN BE EITHER A VERTICAL VENT

 

 

OR HORIZONTAL VENT

Figure 4

THERMOSTAT OPERATION

To turn on burner, rotate dial knob toward setting number 7. To shut down burner, rotate dial knob toward setting number 1.

The dial numbers 1 to 7 correspond to 50o to 90oF (10o to 32oC). This temperature at the bulb thermostat, not the room tempera- ture. The owner is advised to determine the particular heat setting that is desired for comfort, as heating requirements are different for every owner.

Attention: If no heat is desired, turn the gas control knob to the PILOT position.

12822-3-0406

Page 8

Page 8
Image 8
Empire Products RH-50-6 installation instructions Vent Safety Shutoff System, Thermostat Operation

RH-50-6 specifications

The Empire Products RH-50-6 is a cutting-edge heating solution designed to provide efficient warmth and comfort in residential and commercial settings. Known for its robust construction and high-performance features, the RH-50-6 has become a popular choice among consumers looking for reliability and efficiency in heating.

One of the standout characteristics of the Empire RH-50-6 is its impressive heating capacity. With a powerful output designed to warm larger areas, this unit is ideal for spaces such as living rooms, basements, or even commercial environments. The RH-50-6 utilizes an advanced heating technology known as radiant heat, which warms objects and surfaces in the room directly, providing a consistent and comfortable temperature throughout the space.

Another key feature of the RH-50-6 is its sleek design. The modern aesthetics are complemented by a user-friendly interface, making it easy for homeowners to control their heating experience. The unit comes equipped with a digital thermostat that enables precise temperature regulation, allowing users to set their desired level of comfort with ease. Additionally, the thermostat can be programmed to maintain specific temperatures at different times of the day, optimizing energy usage and enhancing convenience.

The Empire RH-50-6 also prioritizes safety, equipped with several built-in safety features, including an automatic shut-off mechanism that activates if the unit overheats. This ensures peace of mind for users, particularly in family environments. The unit is designed to operate quietly, contributing to a serene atmosphere while maintaining warmth without disruptive noise levels.

Moreover, the Empire Products RH-50-6 emphasizes energy efficiency. The innovative design minimizes energy consumption while maximizing output, aligning with modern environmental standards and helping users reduce their utility bills. This eco-friendly characteristic makes it an attractive choice for those who are conscious of their environmental impact.

In summary, the Empire Products RH-50-6 stands out for its combination of powerful performance, user-friendly technology, and safety features. Whether for a large home or a commercial space, its ability to provide efficient and consistent heating is a testament to Empire’s commitment to quality and innovation. The RH-50-6 is not just a heating solution; it represents a blend of style, efficiency, and comfort that consumers can trust.