EMULEX MODEL 355 SAN STORAGE SWITCH
USERS GUIDE CHAPTER 3: SWITCH MANAGEMENT
EMULEX CORPORATION 50
PART NUMBER 00041407-002 REV. B
Viewing Port Diagnostics

This page displays diagnostic information pertaining to each port in the switch. Use the information

provided on this page to diagnose abnormally high error counts on a particular port.

To view the current diagnostic settings:

Click Advanced Functions > Diagnostics > Port.

The Port Diagnostics page appears.

Statistic Description
Port & Health Color Indicators
• Green
• Yellow
• Red
See “Port Utilization and Health” on page 46 for descriptions of the healt h
indicators.
Insertion Count Number of times this port has been inserted into the network since the switch
was reset or the counters were cleared.
CRC Errors Number of CRC errors that are detected in frames passing through this port
since the switch was reset or the counters were cl eared.
Ordered Set Errors Number of Ordered Sets that are received on this por t with an encoding error
since the switch was reset or the counters were cl eared.
Clock Delta Difference (in parts per million) between the internal switch clock and the
received clock signal on the port.
State Current state of this port – either inserted or bypa ssed
Beacon Port Forces both port LEDs to flash on and off continuously. Use this to l ocate and
take action on a specific port. The flashing override s normal port indication
until beaconing is turned off; however, port operation continues to operate
normally.
Figure 3-30: Port Diagnostics page