Enerco 4000ID, 2000ID 3000ID, 1000ID owner manual Maintenance, Ventilation, Description

Models: 4000ID 3000ID 2000ID 3000ID 1000ID

1 36
Download 36 pages 45.65 Kb
Page 5
Image 5
Maintenance

The hot air heaters with wheels must be wheeled. The suspended version which has no wheels must be transported with adequate machinery.

Maintenance

Preventive and regular maintenance will ensure a long trouble free life to your heater.

Ventilation Warning

Never service heater while it is plugged in, operating or hot.

Severe burns or electrical shock can occur.

Every 50 hours of operation: disassemble filter and wash with clean oil, remove upper body parts and clean inside and ventilator with compressed air, check correct attachment of H.T. connectors to the electrodes and check H.T. cables, remove burner assembly, clean and check electrode settings, adjust according to scheme

“GAP OF ELECTRODES”.

Flue Connections Diagram

Ventilation

6 “

Description

A)Minimal 39”

B)Minimal 39”

C)The shortest

D)The same or bigger than the smokes outlet diameter of heater

E)Minimal 1m

1)Anti-wind device provided with the heater

2)Horizontal crossing with minimal upside angle pitch of 5°

3)Chimney 8” x 8” of minimal inside measure

4)Chimney anti-explosion flap door

5)External seating wall

6)Chimney ending H shape

N.B. Above recommendation indicative only. Have your installation checked by local authority.

C

D Description

2

3

B

 

A

Manual background1

5

Manual background 4

6

 

E

 

 

C

 

D

 

2

 

B

A

1

 

5

 

ENERCO GROUP, INC. Indirect Fired Portable Heater

5

Operating Instructions and Owner’s Manual

Page 5
Image 5
Enerco 4000ID, 2000ID 3000ID, 1000ID owner manual Maintenance, Ventilation, Description