Enerco 7000ID owner manual General Recommendations, Technical Specifications, 4000ID, hd7000id

Models: 7000ID

1 28
Download 28 pages 36.61 Kb
Page 3
Image 3
General Recommendations

Important

Before using the heater, read and understand all instructions and follow them carefully. The manufacturer is not responsible for damages to goods or persons due to improper use of units.

General Recommendations

The heater is designed and approved for use as a construction heater in accordance with Standard ANSI Z83.7 - CGA 2.14.

Intended use is the temporary heating of buildings or structures under construction, alteration or repair.

Warning

TECHNICAL SPECIFICATIONS CHECK WITH YOUR LOCAL FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.

Here are a few general guidelines which should be followed:

Follow the instructions in this booklet very carefully.

Don’t install the heater in places where there may be a risk of fire or explosion.

Inflammable material should be kept at a safe distance from the heater (Minimum 6 feet).

All fire prevention regulations must be adhered to.

The room or building which is being heated must be sufficiently ventilated so that the heater has enough air to function properly.

The heater must be near a chimney or chimney flue and a suitable electric switchboard.

Don’t let animals or children near the heater.

Make sure heater is inspected before each use, and at least annually by a qualified service person.

After use make sure the disconnecting switch is off. When using any type of space heater it is obligatory: not to exceed the maximum level of heat output of the furnace

(“TECHNICAL SPECIFICATIONS TABLE”).

To make sure that there is adequate air circulation and air supply to the heater and that nothing is obstructing the aspiration and expulsion of air; movement of air may be obstructed in various ways including placing covers or other objects on the heater or positioning the heater too near a wall or other large object. If the airflow is not adequate, the combustion chamber will overheat and the overheat safety thermostat L1 will turn the burner off and on continuously (“troubleshooting”).

TECHNICAL SPECIFICATIONS

4000ID

4000ID

7000id

hd7000id

 

 

 

 

 

 

 

 

Heat input

 

[kBTU/h]

400

400

700

700

 

 

 

 

 

 

 

 

Air flow

 

[cfm]

4.240

4.240

7.420

7.420

 

 

 

 

 

 

 

 

Heat output

 

[kBTU/h]

340

340

595

595

 

 

 

 

 

 

 

 

Oil N”2 Max fuel

 

[LBH]

20.4

20.4

35.8

35.8

consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Natural gas fuel

 

[CFH]

391.4

391.4

684.9

684.9

consumption

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Propane fuel consumption

[CFH]

157.0

157.0

274.7

274.7

 

 

 

 

 

 

 

 

 

 

Phase

 

1

1

1

1

 

 

 

 

 

 

 

 

Power supply

 

Voltage

[V]

120

220

220

220

 

 

 

 

 

 

 

 

 

 

Frequency

[Hz]

60

60

60

60

 

 

 

 

 

 

 

 

Electric consumption

[W]

1.240

1.760

2.120

2.300

 

 

 

 

 

[A]

13.5

14.5/5.8

7.0

14.8

 

 

 

 

 

 

 

 

 

Diesel burner model

 

Riello 40 F10

Riello 40 F15

 

 

 

 

 

 

 

Nozzle

 

[USgalll1]

2.25 GPH 600 B

2.25 GPH 60’ B

3.50 GPH 60’ B

3.50 GPH 60’ B

 

 

 

 

 

 

Gas burner model

 

Riello 40 G400

Riello 40 G750

(nalural gas or propane)

 

 

 

 

 

 

 

 

 

 

 

 

Gas supply pressure:

 

min 4” w.c. max 10” w.c.

min 7” w.c. max 14” w.c.

natural gas

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas supply pressure:

 

min 8” w.c. max 13” w.c.

min 8” w.c max 14” w.c.

propane

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static pressure

 

[lnWC]

0.4

0.8

0.4

0.8

 

 

 

 

 

 

 

Flue diameter

 

[In]

5.9

5.9

7.9

7.9

 

 

 

 

 

 

Compulsory flue draft

[lnWC]

0.05

0.05

0.05

0.05

 

 

 

 

 

 

Maximum air temperature

°F

250.0

250.0

250.0

250.0

 

 

 

 

 

 

Dimensions. L x W x H

[In]

72x31x43

82x31x43

85x35x53

101x35x53

 

 

 

 

 

 

 

 

Weight

 

[Ib]

353

364

550

562

 

832 (HD Version)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENERCO GROUP, INC. Indirect Fired Portable Heater

3

Operating Instructions and Owner’s Manual

Page 3
Image 3