IT’S THE RIGHT HEAT
FOR THE RIGHT JOB.
•Safe - Heater shuts off with loss of flame or power supply
•Instant Heat - Economical, efficient, and clean burning
•Maximum Heat Circulation -
•Made To Last - Rugged, durable steel construction
•Ready To Use - Simple
•CSA Certified
•Limited
◗Temporary Heat For Smaller Jobs
CSA Certified
◗Temporary Heat For Smaller Jobs
HS35FA
35,000 BTU/HR
F170035
Heats up to 800 square feet. Operates up to 12 hours from a 20 lb. BBQ type propane tank.
HS55FAV | HS85FAV | HS125FAV |
F170055 | F170085 | F170125 |
Heats up to 1,250 | Heats up to 2,000 | Heats up to 3,000 |
square feet. Operates | square feet. Operates | square feet. Operates |
up to 14 hours from a | up to 8 hours from a | up to 11 hours on a |
20 lb. BBQ type propane | 20 lb. BBQ type propane | 40 lb. or larger |
tank on low setting. | tank on low setting. | propane tank. |
◗Temporary Heat For Larger Jobs
HS170FAVT |
| HS170NG |
| HS400FAVT |
| ||||
|
| 150,000 BTU/HR |
|
| |||||
| F170170 |
|
|
| F170180 |
|
| F172425 |
|
| Heats up to 4,000 |
| Heats up to 3,500 |
| Heats up to 9,000 |
| |||
| square feet. Operates |
| square feet. Operates |
| square feet. Operates |
| |||
| up to 17 hours on a |
|
|
| on natural gas. |
| up to 17 hours on |
| |
| 100 lb. propane tank. |
|
|
|
|
| two, 100 lb. propane |
| |
|
|
|
|
|
|
| tanks on low setting. |
| |
|
|
|
|
|
|
|
|
|
|
|
| HS35FA | HS55FAV |
| HS85FAV | HS125FAV | HS170FAVT | HS170NG | HS400FAVT |
| Stock Number | F170035 | F170055 |
| F170085 | F170125 | F170170 | F170180 | F172425 |
| Output (BTU/HR) | 35,000 | 30,000 - 55,000 |
| 50,000 - 85,000 | 75,000 - 125,000 | 125,000 - 170,000 | 150,000 | 250,000 - 400,000 |
| Output CFM | 100 | 300 |
| 300 | 350 | 450 | 450 | 1400 |
| Fuel | Propane Gas | Propane Gas |
| Propane Gas | Propane Gas | Propane Gas | Natural Gas | Propane Gas |
| Min. Required Tank Size | 20 lb. | 20 lb. |
| 20 lb. | 40 lb. | 100 lb. | – | 100 lb. |
|
|
|
|
|
|
|
|
|
|
| Propane Consumption (lbs/hr) | 1.6 | 1.2 to 2.08 |
| 2.3 to 3.9 | 3.5 to 5.8 | 5.8 to 7.8 | 138 cub. ft. / hr. | 11.5 to 18.5 |
| Pressure Regulator Settings | 10 PSI | 28” W.C. |
| 28” W.C. | 28” W.C. | 28” W.C. | 4” | 20 PSI |
| Adjustable Height Control | – | Yes |
| Yes | Yes | Yes | Yes | – |
| Flame Safety | Yes | Yes |
| Yes | Yes | Yes | Yes | Yes |
| High Temperature Limit Switch | 240º F | 240º F |
| 240º F | 240º F | 240º F | 240º F | 240º F |
| Ignition | Piezo | Continuous |
| Continuous | Continuous | Automatic Solid State | Automatic Solid State | Automatic Solid State |
| Thermostat | – | – |
| – | – | |||
| Power Required | 115 V. 60 Hz 3a | 115 V. 60 Hz 3a |
| 115 V. 60 Hz 3a | 115 V. 60 Hz 3a | 115 V. 60 4a | 115 V. 60 4a | 115 V. 60 4a |
| 1/4” I.D. w/ Regulator and POL | 3/8” I.D. w/ Regulator and POL |
| 3/8” I.D. w/ Regulator and POL | 3/8” I.D. w/ Regulator and POL | 3/8” I.D. w/ Regulator and POL | – | 1/4” I.D. w/ Regulator and POL | |
| POL/Excess Flow Check Valve | Yes | Yes |
| Yes | Yes | Yes | – | Yes |
| Shipping Size (L x W x H) | 19” x 11.5” x 14” | 18.5” x 11.5” x 14” |
| 21” x 11.5” x 16” | 20.25” x 12” x 15.5” | 26.5” x 11.5” x 16.75” | 26.5” x 11.5” x 16.75” | 38.58” x 15” x 22.25” |
| Net Weight (Includes Hose / | 15 lbs. | 16 lbs. |
| 18 lbs. | 23 lbs. | 32 lbs. | 32 lbs. | 47 lbs. |
| Regulator / POL Assembly) |
|
|
|
|
|
|
|
|
| Shipping Weight | 17 lbs. | 20 lbs. |
| 20 lbs. | 25 lbs. | 34 lbs. | 34 lbs. | 51 lbs. |
| Shipping Cube | 1.8’ | 1.7’ |
| 2.2’ | 2.7’ | 3.0’ | 3.0’ | 7.5’ |
|
|
|
|
|
|
|
|
|
|
| www.enerco.com |
|
|
| Enerco Group Inc. 4560 West 160th St. Cleveland, Ohio 44135 • |
L206