Enerco HS170FAVT manual It’S The Right Heat For The Right Job, HS35FA, HS55FAV, HS85FAV, HS125FAV

Models: HS170FAVT

1 2
Download 2 pages 30.73 Kb
Page 2
Image 2
IT’S THE RIGHT HEAT

ITS THE RIGHT HEAT

FOR THE RIGHT JOB.

Safe - Heater shuts off with loss of flame or power supply

Instant Heat - Economical, efficient, and clean burning

Maximum Heat Circulation - Heavy-duty, high output fan

Made To Last - Rugged, durable steel construction

Ready To Use - Simple hook-up; hose and regulator included

CSA Certified

Limited 1-Year Warranty

Temporary Heat For Smaller Jobs

CSA Certified

Temporary Heat For Smaller Jobs

HS35FA

35,000 BTU/HR

F170035

Heats up to 800 square feet. Operates up to 12 hours from a 20 lb. BBQ type propane tank.

HS55FAV

HS85FAV

HS125FAV

30,000-55,000 BTU/HR

50,000-85,000 BTU/HR

75,000-125,000 BTU/HR

F170055

F170085

F170125

Heats up to 1,250

Heats up to 2,000

Heats up to 3,000

square feet. Operates

square feet. Operates

square feet. Operates

up to 14 hours from a

up to 8 hours from a

up to 11 hours on a

20 lb. BBQ type propane

20 lb. BBQ type propane

40 lb. or larger

tank on low setting.

tank on low setting.

propane tank.

Temporary Heat For Larger Jobs

HS170FAVT

 

HS170NG

 

HS400FAVT

 

125,000-170,000 BTU/HR

 

 

150,000 BTU/HR

 

250,000-400,000 BTU/HR

 

 

F170170

 

 

 

F170180

 

 

F172425

 

 

Heats up to 4,000

 

Heats up to 3,500

 

Heats up to 9,000

 

 

square feet. Operates

 

square feet. Operates

 

square feet. Operates

 

 

up to 17 hours on a

 

 

 

on natural gas.

 

up to 17 hours on

 

 

100 lb. propane tank.

 

 

 

 

 

two, 100 lb. propane

 

 

 

 

 

 

 

 

tanks on low setting.

 

 

 

 

 

 

 

 

 

 

 

 

 

HS35FA

HS55FAV

 

HS85FAV

HS125FAV

HS170FAVT

HS170NG

HS400FAVT

 

Stock Number

F170035

F170055

 

F170085

F170125

F170170

F170180

F172425

 

Output (BTU/HR)

35,000

30,000 - 55,000

 

50,000 - 85,000

75,000 - 125,000

125,000 - 170,000

150,000

250,000 - 400,000

 

Output CFM

100

300

 

300

350

450

450

1400

 

Fuel

Propane Gas

Propane Gas

 

Propane Gas

Propane Gas

Propane Gas

Natural Gas

Propane Gas

 

Min. Required Tank Size

20 lb.

20 lb.

 

20 lb.

40 lb.

100 lb.

100 lb.

 

 

 

 

 

 

 

 

 

 

 

Propane Consumption (lbs/hr)

1.6

1.2 to 2.08

 

2.3 to 3.9

3.5 to 5.8

5.8 to 7.8

138 cub. ft. / hr.

11.5 to 18.5

 

Pressure Regulator Settings

10 PSI

28” W.C.

 

28” W.C.

28” W.C.

28” W.C.

4”

20 PSI

 

Adjustable Height Control

Yes

 

Yes

Yes

Yes

Yes

 

Flame Safety

Yes

Yes

 

Yes

Yes

Yes

Yes

Yes

 

High Temperature Limit Switch

240º F

240º F

 

240º F

240º F

240º F

240º F

240º F

 

Ignition

Piezo

Continuous

 

Continuous

Continuous

Automatic Solid State

Automatic Solid State

Automatic Solid State

 

Thermostat

 

Built-in

Built-in

Built-in

 

Power Required

115 V. 60 Hz 3a

115 V. 60 Hz 3a

 

115 V. 60 Hz 3a

115 V. 60 Hz 3a

115 V. 60 4a

115 V. 60 4a

115 V. 60 4a

 

Hose-10ft.

1/4” I.D. w/ Regulator and POL

3/8” I.D. w/ Regulator and POL

 

3/8” I.D. w/ Regulator and POL

3/8” I.D. w/ Regulator and POL

3/8” I.D. w/ Regulator and POL

1/4” I.D. w/ Regulator and POL

 

POL/Excess Flow Check Valve

Yes

Yes

 

Yes

Yes

Yes

Yes

 

Shipping Size (L x W x H)

19” x 11.5” x 14”

18.5” x 11.5” x 14”

 

21” x 11.5” x 16”

20.25” x 12” x 15.5”

26.5” x 11.5” x 16.75”

26.5” x 11.5” x 16.75”

38.58” x 15” x 22.25”

 

Net Weight (Includes Hose /

15 lbs.

16 lbs.

 

18 lbs.

23 lbs.

32 lbs.

32 lbs.

47 lbs.

 

Regulator / POL Assembly)

 

 

 

 

 

 

 

 

 

Shipping Weight

17 lbs.

20 lbs.

 

20 lbs.

25 lbs.

34 lbs.

34 lbs.

51 lbs.

 

Shipping Cube

1.8’

1.7’

 

2.2’

2.7’

3.0’

3.0’

7.5’

 

 

 

 

 

 

 

 

 

 

 

www.enerco.com

 

 

 

Enerco Group Inc. 4560 West 160th St. Cleveland, Ohio 44135 • 800-251-0001

L206

Page 2
Image 2
Enerco HS170FAVT manual It’S The Right Heat For The Right Job, HS35FA, HS55FAV, HS85FAV, HS125FAV, HS170NG, HS400FAVT