The connection of Model 35LP to an LP-Gas cylinder must be made in a well ventilated area using the regulator and hose assembly supplied with the appliance. DO NOT attempt to adjust this regulator. It has been preset at the factory to provide safe and proper operation of the appliance. Use a 7/8” open end wrench to connect the POL fitting (supplied with the LP regulator) to the LP-Gas cylinder. Turn the POL nut in a counter- clockwise direction (left hand thread) until tight. DO NOT use pipe compound on POL threads.

The heater must be located at least six feet away from any LP- Gas cylinder and must not be directed toward any LP-Gas cylinder within 20 feet. If more than one heater is used, they and the supply cylinders must be separated by at least 20 feet.

The gas supply must be turned off at the LP-Gas supply cylinder when the heater is not in use.

When the heater is to be stored indoors, the connection between the LP-Gas supply cylinder and the heater must be disconnected and the cylinder removed from the heater and stored in accordance with Chapter 5 of the Standard for the Storage and Handling of Liquefied Petroleum Gases, ANSI/NF-PA 58 (U.S.), OR CAN/CGA B149.2 (Canada).

If connected to a permanently installed LP Gas supply system, the system requires the use of a two-stage gas regulator assembly which is normally provided by your LP-Gas dealer as part of the LP-Gas supply system. Consult with your local LP-Gas dealer for details concerning proper equipment and installation.

Piping must be clean and free from scale or burr.

Before attempting to ignite the appliance, all gas fittings and connections must be thoroughly checked for gas leaks. Apply a small amount of a mild soap and water solution to all fittings and connections and observe for escaping bubbles. If any leaks are detected, shut off the gas supply to the appliance immediately. Wait a minimum of five minutes, repair the leak(s) and retest for leakage. Dry all fittings and connections after leak testing.

WARNING

NEVER USE A FLAME FOR GAS LEAK TESTING.

OPERATING INSTRUCTIONS

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTION EXACTLY, A FIRE OREXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

CAUTION

THIS APPLIANCE IS HOT DURING

NORMAL OPERATION. AVOID

PHYSICAL CONTACT.

CAUTION

DO NOT PLACE CLOTHING OR

OTHER COMBUSTIBLE MATERIALS

ON THIS APPLIANCE.

DO NOT operate this heater if any part has been under water. Call a qualified service technician to inspect the appliance and to replace any part of the control system or gas control valve which has been under water.

This appliance must be installed and operated only in locations where the potential for physical damage to the appliance is reduced to a minimum. The owner/operator of this appliance must ensure that precautions are taken to protect the appliance from physical damage.

LIGHTING AND SHUT-DOWN

Lighting the Heater:

1.Before attempting to light the heater, smell all around the heater area for gas. Be sure to smell next to the floor because LP-Gas is heavier than air and will settle on the floor. Turn on the gas supply to the appliance and check all fittings and connections for gas leaks using a mild soap and water solution. NEVER use a match to check for gas leaks. Should a gas leak occur, shut off the gas supply to the appliance immediately. Wait a minimum of five minutes before repairing the leak.

2.Use only the fuel intended for this appliance. Check the appliance rating plate for the correct fuel information.

3.Turn off the main gas supply to the appliance. Wait five minutes.

4.Turn on the main gas supply.

5a. Depress and turn Control Knob counterclockwise to “Pilot” position and hold for 1-2 minutes. This may take longer to purge air from the supply hose depending on the length of the hose being used.

Depress red spark ignition button to light pilot flame (repeat until pilot lights) and continue to hold Control Knob at “Pilot” positionfor 30-60 seconds to enable Pilot Light Safety System.

Fully turn Control Knob to “Hi” position to light burner. or...

5b. With a lighted match held to the burner face, depress and hold the reset button. After the burner ignites, hold the reset button depressed for about one minute or until the burner stays lit when the reset button is released. DO NOT light the gas at the burner orifice. DO NOT face heater when attempting to light. Always stand to the side of the unit when lighting.

NOTE: In cases where long runs of gas supply lines have been installed ahead of the appliance, it may be necessary to bleed trapped air out of the supply lines before lighting the burner.

New installations generally require bleeding of supply lines. Wait a minimum of five minutes after bleeding the supply lines before attempting to light the heater.

6.IMPORTANT: DO NOT attempt to adjust the main burner input using the main gas supply valve, for this may cause the thermocouple to shut down the burner.

Enerco Group, Inc. Gas-Fired Infra-Red Portable Construction Heater

4

Operating Instructions and Owner’s Manual

Page 4
Image 4
Enerco HS35LP manual Operating Instructions, Lighting and SHUT-DOWN, Lighting the Heater

HS35LP specifications

The Enerco HS35LP is a high-performance propane heater designed for both residential and commercial use. Known for its portability and efficiency, this unit is a favorite among contractors, outdoor enthusiasts, and anyone needing supplemental heat during colder months.

One of the standout features of the HS35LP is its heating capacity. The heater boasts a remarkable output of 35,000 BTUs, making it capable of warming large spaces quickly and effectively. Whether used in a garage, workshop, or at an outdoor event, this heater can easily handle areas up to 800 square feet, ensuring comfort even in the most frigid conditions.

The HS35LP incorporates advanced infrared heating technology. This means that rather than just heating the air, it warms objects and people directly, providing a cozy atmosphere without the drafts often created by traditional heaters. This direct heating approach is particularly energy-efficient, as it minimizes energy loss associated with heating air that quickly escapes.

Safety is a paramount concern for Enerco, and the HS35LP reflects this commitment. It features a reliable low-oxygen shut-off system that shuts the unit down if oxygen levels drop too low, preventing any risk of carbon monoxide buildup. Additionally, the heater is equipped with a sturdy frame and an anti-tip design, ensuring that it remains stable during operation, which is essential in busy work environments or outdoor settings.

In terms of convenience, the HS35LP has an easy-to-use push-button ignition, allowing for quick starts without the need for matches or lighter fluid. Its compact and lightweight design makes it portable enough for anyone to move around with ease. Moreover, the heater runs on standard 20-pound propane tanks, which are widely available, ensuring you can keep it running without hassle.

Durability is another hallmark of the Enerco HS35LP. Built with high-quality materials, this heater can withstand the rigors of frequent transport and use. Its rugged construction means that it's not only suitable for home use but can also excel in industrial environments where reliability is critical.

In summary, the Enerco HS35LP stands out as a powerful, efficient, and safe heating option. With its robust features, innovative technology, and user-friendly design, it offers an ideal solution for anyone needing effective heat in various settings.